3Com S330 manual Configuring In-band Management

Models: S330

1 262
Download 262 pages 1.1 Kb
Page 85
Image 85

Configuring In-band Management 73

Figure 45 Add Virtual Circuit Menu

3Build a PVC on the far-end PathBuilder S330/S310, using the MCPU as side A of the circuit. Set the following parameters on the Add Virtual Circuit screen:

Shaper Number—Choose the number corresponding to the desired shaper value. You assign the shaper number from the MCPU Shapers screen. See “Configuring MCPU Shapers” in Chapter 4, for details.

IP Address—You must use a different subnet than the one you used for the near-end PathBuilder S330/S310.

Subnet Mask—Specify any acceptable address (for example, 255.255.255.0)

VPI/VCI—You must use the same values as you did for the near-end PathBuilder S330/S310.

4On the Manage IP Network Configuration menu, select [3] Default Gateway Configuration and set the following:

a Set the default gateway on the far-end PathBuilder S330/S310 to the PVC IP address you set for the near-end PathBuilder S330/S310 in step 1.

b Set the default gateway on the management station to the local host IP address of the near-end PathBuilder S330/S310.

For details about setting the default gateway, see “Configuring the Default Gateway” earlier in this chapter.

5Apply your IP configuration changes.

a From the main menu, select [1] System Administration.

b From the System Administration menu, select [3] Manage IP Network Configuration.

c From the Manage IP Network Configuration menu, select [1] Local Host IP Configuration.

d From the Local Host IP Configuration menu, select [2] Apply IP Configuration Changes.