Managing System Alarms 171

DS1/E1 UNI Module Alarms

Table 28 describes the alarms specific to the DS1 UNI and E1 UNI modules.

ATM Forum required alarms are indicated by the notation ATM Forum (R-xxx), where xxx is the required alarm number.

Table 28 DS1/E1 UNI Module Alarms

Alarm

Meaning

Troubleshooting Steps

AFA Link Removal Automatic Frequency Adjustment - Link removed from physical line group due to error rate in CRC check of T1/E1 exceeding user specified rate for a given period of time.

Check the removed link for the CRC errors.

Bad IMA ID

A link within the group has

 

received an IMA ID from the far

 

end that is different than when

 

the group was initialized (and

 

from the other links in the

 

group). The link with the bad

 

IMA ID is probably

 

misconnected.

Check the links for proper connection. Reconnect if necessary.

Bad Link ID

Each IMA group assigns a

 

unique Transmit link ID to each

 

link in the group. This link ID

 

should match the Receive link

 

ID of the remote end IMA

 

device. This alarm means that a

 

link was operating correctly,

 

but then received a Transmit

 

link ID already assigned to a

 

previous link.

 

A Tx Misconnected alarm is

 

also generated.

Bad M

The far end frame size M has

 

changed in an IMA link.

 

The maximum value for the

 

frame size on the local device’s

 

serial card must match the

 

maximum value for the frame

 

size of the connected device.

 

The link with the BAD M is

 

probably misconnected.

Check the links for proper connection. Reconnect if necessary.

Check to make sure the maximum frame size is set to the same value on the local and remote ends.

Bad Offset

Far end ICP cell offset has

 

changed in an IMA link.

 

Each IMA group assigns a

 

unique Transmit offset to each

 

link in the group. This alarm

 

means that a link was

 

operating correctly, but then

 

received a Transmit offset

 

already assigned to a previous

 

link.

 

A Tx Misconnected alarm is

 

also generated.

(continued)

 

Check the links for proper connection. Reconnect if necessary.

Page 183
Image 183
3Com S330 manual DS1/E1 UNI Module Alarms