xCHAPTER : WARNING INFORMATION

Power and Power

This equipment is not intended for use with IT power distribution systems

Cords

whose line to line voltage exceeds 250 VAC RMS defined by EN 60950 as

 

having no direct connection to earth. The PathBuilder S330/S310 will

 

auto-configure for 115 VAC or 220-240 VAC.

 

NORTH AMERICAN APPLICATIONS: Use a UL Listed and CSA Certified Cord Set

 

rated 6 amps, consisting of a minimum 18 AWG, Type SVT or SJT three

 

conductor cord maximum of 15 feet in length, with a NEMA 5-15P plug.

 

INTERNATIONAL APPLICATIONS: The power supply cords used with this

 

equipment should be harmonized with all local standards applicable in the

 

country in which it is installed.

 

Safety agency compliance requires this unit to be connected to branch circuits

 

with overcurrent protection 20A for North American applications and 10A

 

for international applications.

 

The power supply cord must be disconnected when servicing all components or

 

subsystems.

 

 

EMI

FCC - This equipment generates, uses, and can radiate radio frequency energy,

 

and if not installed and used in accordance with the instruction manual, may

 

cause interference to radio communications. It has been tested and found to

 

comply with the limits for a Class A computing device pursuant with Part 15 of

 

the FCC Rules, which are designed to provide reasonable protection against

 

such interference when operated in a commercial environment. Operation of

 

this equipment in a residential area is likely to cause interference, in which case

 

the user at his own expense will be required to take whatever measures may be

 

required to correct the interference. These tests were conducted with shielded

 

communications cables with metal connector hoods; the use of unshielded

 

cables may void this compliance.

 

Canada - This digital apparatus does not exceed the Class A limits for radio

 

noise emissions from digital apparatus set out in the Radio Interference

 

Regulations of the Canadian Department of Communications.

 

Europe - This is a Class A product. In a domestic environment this product may

 

cause radio interference, in which case, the user may be required to take

 

adequate measures.

Safety Classification of Ports for Connection to Telecommunications Networks

The following port types in the product range are classified according to the Harmonized Europeans Standard EN41003, subclause 4.1.3, as follows:

E1/E3 - TNV normally operating within SELV limits (TNV-1)

1Telecommunications Network Voltage (EN60950, subclause 1.2.8.8)

2Safety Extra-Low Voltage (EN60950, subclause 1.2.8.5)

Page 10
Image 10
3Com S330 manual Power and Power, Cords