INSTALLATION CODES AND STANDARDS
The steamer must be installed in accordance with:
In the United States of America:
1.State and local codes.
2.National Electrical Code,
In Canada:
1.Local codes.
2.Canadian Electric Code, CSA C22.2 (latest edition). Copies may be obtained from The Canadian Standard Association, 5060 Spectrum Way, Suite 100, Mississauga, Ontario, Canada L4W 5N6.
LEVELING
The steamer must be level for proper operation. Place a carpenter's level on top of the steamer. Level the steamer front to back and side to side by turning the adjustable feet.
ELECTRICAL CONNECTIONS
WARNING: ELECTRICAL AND GROUNDING CONNECTIONS MUST COMPLY WITH THE APPLICABLE PORTIONS OF THE NATIONAL ELECTRICAL CODE AND/OR OTHER LOCAL ELECTRICAL CODES.
When making electrical connections, use copper wire suitable for at least 200°F (90°C). The steamer must be grounded. The wiring diagram is located on the inside of the right panel.
Steamers wired for 1 phase can be changed to 3 phase or vice versa by relocating the jumper wires on the terminal block as shown on the wiring diagram.
ELECTRICAL DATA
Model | Volts | KW | Amp @ 1 PH | Amp @ 3 PH | ||
|
| 208 | 6 | 28.9 | NA | |
|
| 9 | 43.3 | 25 | ||
|
|
| ||||
VPX3 | 240 | 6 | 25 | NA | ||
9 | 37.5 | 21.7 | ||||
|
|
| ||||
|
| 480 | 6 | 12.5 | NA | |
|
| 9 | 18.8 | 10.9 | ||
|
|
| ||||
|
| 208 | 10 | 48.1 | NA | |
|
| 15 | 72.2 | 41.7 | ||
|
|
| ||||
VPX5 | 240 | 10 | 41.7 | NA | ||
15 | 62.5 | 36.1 | ||||
|
|
| ||||
|
| 480 | 10 | 20.9 | NA | |
|
| 15 | 31.3 | 18.1 | ||
|
|
|