For best results, Vulcan recommends that the water supply meet the following specifications:

Hardness of 2 grains or 35 ppm.

Total dissolved solids (TDS) — 60 ppm.

Ph factor of 7.0 to 7.5.

These specifications can easily be obtained with the use of a properly maintained water softener.

VENT HOOD

Some local codes may require the steamer to be located under an exhaust hood. Information on the construction and installation of ventilating hoods may be obtained from the standard for "Vapor Removal for Cooking Equipment", NFPA No. 96 (latest edition).

BEFORE FIRST USE

Thoroughly clean the steamer before using for the first time. See the CLEANING section in this manual.