Vulcan-Hart ML-760601, WSPR2F, WSPR1, VSP200F Maintenance, Troubleshooting, Cleaning, Service

Models: ML-052823 ML-052822 VSP100 ML-760601 ML-769292 ML-760600 VSP200 VSP200F WSPR1 WSPR2F WSPR2

1 7
Download 7 pages 50.63 Kb
Page 7
Image 7
CLEANING

CLEANING

Top grate(s) may be immersed in strong commercial cleaning compound overnight. In the morning, rinse with hot water to remove any residues of cleaning compound.

Stainless steel surfaces may be cleaned using damp cloth with mild detergent and water solution.

Places where fat, grease, or food can accumulate must be cleaned regularly.

MAINTENANCE

WARNING: THE STOCKPOT RANGE AND ITS PARTS ARE HOT. USE CARE WHEN OPERATING, CLEANING, OR SERVICING.

SERVICE

Contact your local Service Agency for any repairs or adjustments needed on this equipment.

PROBLEM

Pilot Outage

Improper burner combustion

Poor Ignition

TROUBLESHOOTING

POSSIBLE CAUSES

1.Pilot flame too low

2.Restriction in pilot orifice

3.Restriction in pilot valve

Improper ventilation

1.Insufficient gas input

2.Poor air-gas adjustment

3.Restriction in pilot orifice

4.Restriction in main burner ignition port

5.Restriction in control valve

6.Restriction in gas orifice

- 7 -

Page 7
Image 7
Vulcan-Hart ML-760601, WSPR2F, WSPR1, VSP200F, ML-760600, ML-769292, VSP100 Maintenance, Troubleshooting, Cleaning, Service