CT-400 MAINFRAME FEATURES

 

 

 

 

 

 

 

 

 

 

 

FRONT PANEL FEATURES

 

 

 

 

 

 

POWER SWITCH

 

 

 

 

 

 

Feature 1

When elevated, the mainframe is in standby mode, where power is supplied to

 

 

the mainframe, but not to the VXI modules.

 

 

 

 

 

When depressed, power is supplied to both mainframe and VXI modules.

 

VOLTAGE MONITOR INDICATORS

 

 

 

 

 

Feature 2

Indicates whether specific backplane voltages are within specifications. See

 

 

Figure 1-3for details.

 

 

 

 

 

 

 

 

 

 

 

 

REAR PANEL FEATURES

 

 

 

 

 

 

MODULE FAN FILTER

 

 

 

 

 

 

Feature 3

Replaceable component that filters the air that cools the plug-in modules.

 

CHASSIS GROUND TERMINAL

 

 

 

 

 

 

Feature 4

Used to electrical ground the mainframe.

 

 

 

 

J200 CONNECTOR

 

 

 

 

 

 

Feature 5

AC power receptacle.

 

 

 

 

 

F200 CONNECTOR

 

 

 

 

 

 

Feature 6

Fuse location.

 

 

 

 

 

J210 CONNECTOR

 

 

 

 

 

 

Feature 7

Monitor / Control Connector.

 

 

 

 

 

POWER SUPPLY FAN FILTER

 

 

 

 

 

 

Feature 8

Replaceable component that filters the air that cools the power supply.

 

MONITOR BOARD / J211 CONNECTOR

 

 

 

 

 

Feature 9

Provides monitoring of the mainframe’s operation and environment.

 

 

(See Section 1 for more details.)

 

 

 

 

 

POWER SUPPLY

 

 

 

 

 

 

Feature 10

Replaceable power supply unit.

 

 

 

 

 

1

2

5

6

7

8

9

0

1

 

CT-400 SERIES

+5V +12V +24V

+5V Stby

 

 

 

VXI MAINFRAME

-5.2V -12V -24V

-2V

 

 

 

 

 

 

 

 

Voltage Monitors

bus

4

!

WARNING - DO NOT REMOVE THIS POWER MODULE

WHILE THIS INSTRUMENTHAS AC POWER APPLIED

 

 

WARNING - THE GROUNDING CONNECTION IN THE

 

!

POWER CORD MUST BE CONNECTED TO ENSURE

 

PROTECTION FROM ELECTRICAL SHOCK.

 

!

WARNING - TO AVOID ELECTRICALSHOCK, DISCONNECT

 

AC POWER CORD PRIOR TO REPLACING FUSE.

 

 

CAUTION - FOR CONTINUED FIRE PROTECTION

 

 

REPLACE ONLY WITH A FUSE OF THE CORRECT

 

 

VOLTAGE AND RATING.

F200

 

 

15A T 250 (VAC)

REMOVE COVER TO

 

 

SERVICE AIR FILTER

 

J200

PWS

TEMP

100 - 240 VAC

AMB

TEMP

15 A MAX.

PWS

PWR

47 -63 Hz

 

PWS

VOLT

 

PWS

CUR

 

FAN

SPEED

10

VAR

 

 

FAN SPEED

 

HIGH

 

 

LOW

 

 

J201

 

 

MON ITOR / CONTR OL

 

J211

3

J210

1

 

2

 

3

 

4

 

5

 

6

 

7

 

8

 

9

 

1 0

 

1 1

 

1 2

FIGURE 1-2: MAINFRAME FEATURE LOCATIONS

CT-400 Introduction

13

Page 13
Image 13
VXI user manual CT-400 Mainframe Features, Feature Replaceable power supply unit

CT-400 specifications

The VXI CT-400 is an advanced test and measurement platform designed to cater to the needs of engineers and technicians across various industries, including telecommunications, aerospace, and defense. Known for its robust performance and versatility, the CT-400 offers a comprehensive range of features that streamline testing processes, ensuring accuracy and efficiency.

One of the main features of the VXI CT-400 is its modular architecture. This design allows users to configure the system according to their specific requirements, accommodating different testing applications. With a variety of interchangeable modules, users can easily customize their setup for a wide range of tests, from RF and microwave measurements to digital signal processing.

The CT-400 leverages cutting-edge technologies to deliver precise results. Equipped with high-resolution analog-to-digital converters (ADCs) and digital-to-analog converters (DACs), it ensures fidelity in the measurement and reproduction of signals. The device also integrates advanced signal processing algorithms that facilitate enhanced data analysis, making it easier to interpret complex measurement results.

Another notable characteristic of the CT-400 is its support for various communication protocols. This flexibility allows engineers to seamlessly integrate the device into existing test environments, making it compatible with other testing equipment and software platforms. Whether dealing with legacy systems or modern applications, the CT-400's interoperability plays a crucial role in enhancing productivity.

In terms of user experience, the VXI CT-400 is designed with an intuitive interface that simplifies operation. A large, high-resolution display provides clear visualization of measurements, while easy-to-navigate menus enable swift access to different functions. This user-centric design minimizes the learning curve, making it accessible for both experienced professionals and newcomers in the field.

Furthermore, the CT-400 is built with durability in mind. Its rugged construction ensures reliable operation in diverse environments, including harsh industrial settings. This resilience is complemented by robust software support, enabling regular updates and the addition of new features to keep the device up-to-date with technological advancements.

In conclusion, the VXI CT-400 stands out as a powerful test and measurement solution characterized by its modular design, advanced technologies, versatile communication capabilities, intuitive interface, and rugged construction. With these attributes, it serves as an indispensable tool for engineers striving for precision and efficiency in their testing processes.