Parts Overview
Adapter cups
Printer Port
1 | EMPTY | 2 EMPTY |
3 EMPTY
Impedance Test
Impedance of a battery can be a good indicator of degradation of a battery’s performance. In general, the lower the impedance number the better the battery performance during discharge. As a battery ages the impedance starts to rise indicating possible problems with the electrolyte, separator, contact corrosion, or
metal interfaces, all impact the impedance.
The initial impedance of a new battery should be recorded and compared through the life of a battery and a determination can be made to remove the battery from service when the impedance rises out of range.
The Analyzer X3 and X6 produce impedance results within a 15 seconds of testing and displays the impedance in Ohms on the display or on a printout when an optional printer is used.
Follow the directions below for Impedance testing.
This test is only performed in Pocket #1 for the X3 and pockets #1 and #4 for the X6.
SELECTING “IMPEDANCE “
AND RESULTS
ACTION
Analyzer X3 | DISPLAY |
|
FUNCTION BUTTONS
|
|
|
|
|
| On/Off Switch |
|
|
|
|
| Power in Receptacle | |
Serial Port |
|
|
|
|
| Serial Port |
(Computer) |
| (Printer) |
Rear view of Analyzer X3
Hi Power in Receptacle
optional
On/Off Switch
Power in Receptacle
Display After “Turn On”
After the battery is placed in the adapter
PUSH FUNCTION until battery specs appear in the display
NO ACTION
PUSH
PUSH
PUSH
PUSH
NO ACTION
NO ACTION
EMPTY
TO PROCEED PRESS
<FUNCTION>
NICD 700 MAH 7.2V
<FUNCTION> FOR NEXT
NICD 700 MAH 7.2V HAS BEEN SELECTED
QUICK TEST
<FUNCTION> FOR NEXT
CYCLE/AUTO/CONDITION <FUNCTION> FOR NEXT
DIS
<FUNCTION> FOR NEXT
CHARGE BATTERY
<FUNCTION> FOR NEXT
IMPEDANCE TEST
<FUNCTION> FOR NEXT
IMPEDANCE TEST
HAS BEEN SELECTED
Serial Port | Serial Port | |
(Computer) | ||
(Printer) | ||
|
Rear view of Analyzer X6
6
NO ACTION | TESTING |
|
FOR RESULTS PUSH | READY | |
PUSH | BATTERY IMPEDANCE | |
.233 ohms | ||
|
15