Cycle Mode

The Cycle mode will cycle a battery through a charge and discharge cycle, known as Cycle (1). One could Select, Cycle 1, 2 or 3. By selecting cycle 1,2 or 3 all one would be doing is repeating the Charge/discharge number to reflect the chosen Cycle count. Cycle 2 and 3 are often used for incoming quality control of new batteries. The X3 will display the capacity (in percentage of rated capacity and mAH). It should be noted that after the completion of the Cycle function the battery is left in a fully charged state.

SELECTING “ CYCLE 2 “

RESULTS

ACTION

Auto Mode

Life cycle testing can be accomplished by choosing the Auto test. Battery performance for multiple cycles can be evaluated as long as the battery is not removed. Charge and discharge cycles are performed with 10-minute rest in between charge and discharge.

An example of how this test can be used is the following: A manufacturer states that a NiMH battery will Achieve a % of the stated capacity through the 300 cycles through its life (life can be defined as 300 cycles). The 300 cycles can be verified provided that the discharge rate is adjusted per the manufacturer’s specifications.

SELECTING “ AUTO “

RESULTS

ACTION

Display After “Turn On”

After the battery is placed in the adapter

PUSH FUNCTION BUTTON until battery

specs appear in the display

NO ACTION

PUSH

NO ACTION

NO ACTION

PUSH

NO ACTION

NO ACTION

EMPTY

TO PROCEED PRESS

<FUNCTION>

NICD 700 MAH 7.2V

<FUNCTION> FOR NEXT

NICD 700 MAH 7.2V HAS BEEN SELECTED

QUICK TEST

<FUNCTION> FOR NEXT

CYCLE/AUTO/CONDITION <FUNCTION> FOR NEXT

CYCLE/AUTO/CONDITION

HAS NEEN SELECTED

CYCLE 2

<FUNCTION> FOR NEXT

CYCLE 2

HAS BEEN SELECTED

TESTING

Display After “Turn On”

After the battery is placed in the adapter

PUSH FUNCTION BUTTON until battery

specs appear in the display

NO ACTION

PUSH

NO ACTION

NO ACTION

PUSH

NO ACTION

NO ACTION

EMPTY

TO PROCEED PRESS

<FUNCTION>

NICD 700 MAH 7.2V

<FUNCTION> FOR NEXT

NICD 700 MAH 7.2V HAS BEEN SELECTED

QUICK TEST

<FUNCTION> FOR NEXT

CYCLE/AUTO/CONDITION <FUNCTION> FOR NEXT

CYCLE/AUTO/CONDITION

HAS BEEN SELECTED

CYCLE 1

<FUNCTION> FOR NEXT

AUTO CYCLE

<FUNCTION> FOR NEXT

AUTO CYCLE

HAS BEEN SELECTED

NO ACTION

READY

NO ACTION

TESTING

 

FOR RESULTS PUSH

CYCLE 2

CAP=88% 616 MAH

 

10

THE ACTUAL READING WHEN YOU PRESS THE FUNCTION BUTTON WILL DEPEND ON WHERE IN THE CYCLE YOU ARE. IT IS FOR THIS REASON WE RECOMMEND PERFORMING THIS TEST WITH A SERIAL PRINTER

PUSH

FOR RESULTS

AUTO CYCLE - PASS 45

CAP= 85% 595 MAH

 

 

11

Page 10
Image 10
W & W Manufacturing X3 & X6 manual Selecting Cycle Results, Selecting Auto Results, Cycle Mode