Wagner SprayTech GM 2000 EACF, GM 2000 EACR manual Maintenance, Decommissioning and cleaning

Models: GM 2000 EACF GM 2000 EACR

1 36
Download 36 pages 45.88 Kb
Page 21
Image 21

GM 2000 EAC - EN

5. MAINTENANCE

Caution

See SAFETY REGULATIONS in chapter 1.

Attention

The spray gun and the system must be cleaned every day. Use only the cleaning sol- vent recommended by the material manufacture.

Never immerse the spray gun into the solvent.

The following points must be observed before every maintenance works:

Switch off control unit.

Relieve spray gun and system pressure.

Secure the spray gun.

5.1Decommissioning and cleaning

1.Switch off control unit.

2.Relieve system pressure and cut off the air supply to the spray gun.

3.Replace material by cleansing agent.

if the round jet nozzle is fitted

4.By means of tip spanner (A), loosen tip insert (B) by a half turn.

5.Remove tip spanner and briefly actuate trigger. Caution, never spray into an enclo- sed vessel.

6.Relieve spray gun and system pressure !

7.Tighten tip insert.

8.Clean the body of the gun with solvent which has been recommended by the paint manufacturer and dry with a cloth or blow gun.

if the flat jet nozzle is fitted

5.Remove and clean the AirCoat tip. (see chapter 4.5)

6.Actuate trigger and thoroughly rinse paint channel. Never spray into an enclosed vessel.

7.Relieve spray gun and system pressure!

8.Clean the body of the gun with solvent which has been recommended by the paint manufacturer and dry with a cloth or blow gun.

Note

Keep the gun pointing downwards or horizontal- ly, cleaning agent must not get into the air ducts.

The gun attachment (X) may only be changed by the WAGNER Service Station.

X

5.1

Page 21
Image 21
Wagner SprayTech GM 2000 EACF, GM 2000 EACR Maintenance, Decommissioning and cleaning, If the round jet nozzle is fitted