Wasp Bar Code CCD Scanner manual Setup & Configuration, To change Minimum/Maximum Length

Models: CCD Scanner

1 44
Download 44 pages 34.76 Kb
Page 8
Image 8

Chapter 5

Setup & Configuration

In order to configure Wasp WCS3900 Series Scanners, you must familiarize yourself with the setup procedures on the following pages. The default settings of the scanners are identified on each page and clearly marked using an asterisk (*). The default settings have been programmed for the most common barcode configurations. Use the setup & configuration barcodes only to customize the WCS3900 Series Scanner settings. If you need to configure the Scanner, the default settings will be overwritten. All the programmed settings are stored permanently in non-volatile memory; therefore, your configuration will be maintained even if the keyboard power to the WCS3900 Series Scanners are removed by turning off your PC.

In order to configure Wasp WCS3900 Series Scanners, two basic steps need to be followed:

(1)Locate the group that contains the options to be changed.

(2)Scan the barcode representing the option to be changed. The scanner will sound two beeps.

To change Minimum/Maximum Length:

(1)Scan the Minimum or Maximum Length barcode on page 15.

(2)Scan a 2 digit value from the ASCII table on pages 31-34

(3)Scan the Minimum or Maximum Length barcode again.

Example: To have a minimum length barcode of 1, you must scan a 0 then 1, then scan the minimum barcode again. To have a maximum length barcode of 10, you must scan a 1 then 0, then scan the maximum barcode again.

6

Page 8
Image 8
Wasp Bar Code CCD Scanner manual Setup & Configuration, To change Minimum/Maximum Length