Quick Setup Guide

Calibrating the Printer

Performing Calibration

Note: This step is very important and must always be carried out whenever media is being changed. Failure to do so will result in mis-detection of the label size.

1.Press and hold the feed button while turning on the power until the printing motor becomes activated.

2.The calibration is complete when the printer automatically feeds the label stock.

3.Press feed button one more time to line label up for printing.

Printing Configuration Report

1.Press and hold the feed button while turning on the power.

2.Continue holding down the feed button.The printer will begin to feed approximately 12” of blank media. The printer will then print a configuration report.This report states the firmware version, ROM checksum, RS232, thermal transfer/direct thermal settings, hardware configuration and font types.

14

Page 18
Image 18
Wasp Bar Code W-300 manual Performing Calibration, Printing Configuration Report