26.Route the wires that attach to the temperature sensor along the copper siphon loop, back to the right side of the heater. Reconnect the wires to the tabs on the back of the control panel (marked as J4-1 and J4-2).

27.Use plastic wire ties to refasten the temperature sensor and high limit switch wires to the copper siphon loop. Bundle the wires near the control panel and fasten them with a wire tie.

28.Replace the flue collector so that the blower mount is in the same position as it was before the heat exchanger reversal. Be sure that the bottom of the flue collector lies flat on the top of the combustion chamber and that it covers all of the heat exchanger tubes. Replace the hex head screws to fasten the flue collector to the combustion chamber.

29.Reassemble the blower and exhaust vent to the flue collector. Be sure that the blower is seated properly on the gasket and fasten it to the flue collector with four hex head screws.

30.Reconnect the fan wires to the terminal strip as follows: (Terminal numbers are shown on wires connected to the bottom of the terminal strip)

a.Black Blower wire to terminal 11

b.Blue Blower wire to terminal 10

c.Red Blower wire to terminal 9

d.Yellow Blower wire to terminal 8

e.White Blower wire to terminal 7

31.Reconnect the two white wires to the vent switch now located just above the return header.

32.Reconnect the blower pressure switch tubing to the blower housing.

33.Replace the EMI shield (metal plate) located over the blower by reinstalling the two hex head screws.

34.Slide the upper right side panel back into the corner posts on the right side of the heater. Push it down until the tabs on the panel lock into the top of the corner posts.

36.Install the flat return header side cover plate (removed from the left side of the heater) on the right side to cover the return header by replacing the four philips head screws, one in each corner.

37.Slide the upper left side panel back into the corner posts on the left side of the heater. Push it down until the tabs on the panel lock into the top of the corner posts.

38.Remove the button plug from the inlet/outlet side cover plate.

39.Reinstall the inlet/outlet header side cover plate located under the inlet/outlet header. It is held with four philips head screws, one in each corner.

3-WAY

JANDY

CHANGEOVER

VALVE

3-WAY

JANDY

CHANGEOVER

VALVE

Figure 15. Typical Water Piping.

Page 14
Image 14
Waterpik Technologies pool/spa heater warranty Typical Water Piping