Wayne-Dalton DS-100, DS-75, DS-50 installation instructions Installing Guides, Installing Brackets

Models: DS-100 DS-50 DS-75

1 15
Download 15 pages 51.66 Kb
Page 5
Image 5
STEP 3 INSTALLING GUIDES

STEP 3 INSTALLING GUIDES

Position the left hand guide 3/8” from the edge of the left hand jamb and loosely clamp in place. Using a level, adjust the guide so that it is plumb and tighten the clamp.

Measure the exact curtain width of the door and add 7/8” to obtain the inside of guide to inside of guide measurement. Use this measurement to locate the right hand guide. Loosely clamp the right hand guide to the jamb. Plumb the guide and tighten the clamp.

Using a string and level, ensure that the tips of the left and right hand guides are level to each other. Shim guides as needed. Double check the inside of guide to inside of guide measurement at top, middle, and bottom to ensure that the guides are plumb and parallel. Fasten both guides to the jambs using the fasteners provided (See Fastener Table in the front of this manual).

IMPORTANT!

IMPORTANT!

Inside of guide to inside of guide measurement must be held to ensure proper door operation.

Use of any other fasteners than those provided must be approved by Wayne-Dalton and cannot be of lesser diameter or grade.

STEP 4 INSTALLING BRACKETS

Install the brackets to the outside of the guides (away from the opening) using two 1/4-20 x 9/16” track bolts in the two holes at the top of the guides, as shown. Loosely install the 1/4-20 flange nuts on the bolts to hold the brackets in place. Check that the brackets are straight and square with one another, shimming if necessary, and fasten the brackets to the wall using the fasteners provided (See Fastener Table in the front of this manual). Tighten the flange nuts on each bracket.

Install the bottom bar stops to the guides as shown using 1/4-20 x 5/8” carriage bolts and flange nuts. Leave the fasteners loose to allow the bottom bar stops to pivot out of the way of the bottom bar angle when the curtain will be pulled into the guides. You will be instructed to tighten the bottom bar stop fasteners in STEP #7.

5

Page 5
Image 5
Wayne-Dalton DS-100, DS-75, DS-50 installation instructions Installing Guides, Installing Brackets

FAQ

What are the measurements for installing the guides?

The exact curtain width of the door plus 7/8 is used to determine the inside of guide to inside of guide measurement for locating and positioning the guides.

Can I use other fasteners for fastening the guides and brackets?

Use of any other fasteners than those provided must be approved by Wayne-Dalton and cannot be of lesser diameter or grade.

What should I do if the bottom bar stops are not pivoting?

Leave the fasteners loose to allow the bottom bar stops to pivot out of the way of the bottom bar angle when the curtain will be pulled into the guides. You will be instructed to tighten the bottom bar stop fasteners in STEP #7.5.