Troubleshooting Chart

Symptom

Possible Cause(s)

Corrective Action

 

 

 

 

 

Motor will not run

1.

Disconnect switch is off

1.

Be sure switch is on

 

2.

Defective wiring

2.

Refer to instructions. Check all connections

Motor runs hot and

1.

Voltage is too low

1.

Check with power company. Use heavier gauge cord

overload kicks off

 

 

 

 

 

2.

Pump house not properly

2.

Be sure pump has sufficient ventilation to cool the motor

 

 

vented

 

 

Motor runs but no

1.

Pump in new installation

water is delivered

 

did not pick up prime

Note: Check prime

 

through:

before looking for

 

a. Improper priming

other causes. Unscrew

 

b. Air leaks

priming plug and see if

 

c. Leaking foot valve

water is in priming

2.

Pump has lost prime

hole.

 

through:

 

 

a. air leaks

 

 

b. water level below suc-

 

 

tion of pump

 

3.

Impeller is plugged

 

4.

Check valve or foot valve

 

 

is stuck in closed position

 

5.

Pipes are frozen

 

6.

Foot valve and/or strainer

 

 

are buried in sand or mud

1.New installation:

a.Re-prime according to instructions

b.Check all connections on suction line

c.Replace foot valve

2.Existing installations:

a.Check all connections on suction line and shaft seal

b.Lower suction line into water and re-prime. If receding water level in well exceeds suction lift, a deep well pump is needed

3.Clean impeller

4.Replace check valve or foot valve

5.Thaw pipes. Bury pipe below frost line. Heat pit or pump house

6.Raise foot valve and/or stainer above well bottom

Pump does not deliver

1.

Water level in well is

water to full capacity

 

lower than estimated

 

2.

Steel piping (if used) is

 

 

corroded or limed, causing

 

 

excess friction

 

3.

Piping is too small in size

1.A deep well jet pump my be needed (over 25 ft. (7.6M) to water)

2.Replace with plastic pipe where possible, otherwise with new steel pipe

3.Use larger piping

3

Page 3
Image 3
Wayne 321602-001 warranty PLS Series, Troubleshooting Chart