Troubleshooting Chart - Back-up Pump

Operating Instructions and Parts Manual

Troubleshooting Chart - Back-up Pump

Symptom

Pump will not run

Possible Cause(s)

1.Connections not secure

2.Low or defective battery

3.Float switch stuck

4.Defective or blown fuse

Corrective Action

1.Check all connections

2.Check battery and replace if low or defective

3.Make sure nothing is interfering with the operation of the switch

4.Check internal fuse located inside the control box. Pull the charger from the wall outlet and remove. If the fuse is blown, replace it with a 15 amp automotive type fuse

Motor hums but

1.

Defective battery

1. Check battery and replace if low or defective

pump won’t run

2.

Impeller is locked

2.

Unplug pump and check to see if impeller is free to turn.

 

 

 

 

If impeller is locked, remove the 4 screws on the bottom of the

 

 

 

 

pump to release the housing around the impeller. Remove the

 

 

 

 

obstruction. Reassemble pump and reconnect

 

 

 

 

 

Pump runs but

1.

Check valve missing or improperly

1.

Check to make sure a check valve is installed and functioning

pumps very little

 

installed

 

between primary pump discharge and Standby Sump Pump

or no water

 

 

 

tee fitting

 

2.

Obstruction in discharge pipe

2.

Check for obstruction and clear if necessary

 

3.

Pump not rotated 30˚

3.

Check that pump is rotated 30˚ in tee fitting

 

4.

Pump air locked

4.

The impeller housing has a small hole on its side. This hole

 

 

 

 

must be open for the pump to prime. With the pump

 

 

 

 

unplugged, remove the 4 screws on the bottom of the pump to

 

 

 

 

release the housing around the impeller. Clean out the hole

 

 

 

 

and replace cover

 

5.

Discharge pipe length and / or

5.

If discharge is too high, a separate line may be required with a

 

 

height exceeds capacity of pump

 

lower discharge height

 

6.

Low or defective battery

6.

Check battery and replace if low or defective

 

 

 

 

 

Pump cycles too

1.

Main check valve located between

1.

Install check va/lve or repair as required

frequently

 

the discharge of the primary

 

 

 

 

pump and the Back-up Sump

 

 

Pump tee fitting or the Back-up Sump Pump flapper valve not installed or working properly

www.waynepumps.com

6

Page 6