Weber 1500 LX owner manual Check for gas leaks, MWARNING Do not ignite burners while leak checking

Models: 1500 LX

1 36
Download 36 pages 1.22 Kb
Page 20
Image 20
Gas supply shut off at the house

Step 13

Check for gas leaks

mDANGER

Do not use an open flame to check for gas leaks. Be sure there are no sparks or open flames in the area while you check for leaks. This will result in a fire or explosion which can cause serious bodily injury or death and damage to property.

mWARNING: You should check for gas leaks every time you disconnect and reconnect a gas fitting.

Note - All factory made connections have been thoroughly checked for gas leaks. The burners have been flame tested. As a safety precaution you should recheck all fittings for leaks before using your Weber Gas Barbecue. Shipping and handling may have loosened or damaged a gas fitting.

mWARNING: Perform these leak checks even if your barbecue was dealer or store assembled.

You will need: soap and water solution and a rag or brush to apply it.

To perform leak checks: Turn ON gas supply at the source. Figure 21.

Figure 21

mWARNING: Do not ignite burners while leak checking.

Check for leaks by wetting the connections with the soap and water solution and watching for bubbles. If bubbles form or if a bubble grows there is a leak.

Note - Since some leak test solutions, including soap and water, may be slightly corrosive, all connections should be rinsed with water after checking for leaks.

Check:

a) Gas supply line to manifold connection. Figure 22 (a).

mWARNING: If there is a leak at connection a, retighten the fitting with a wrench and recheck for leaks with soap and water solution.

If a leak persists after retightening the fitting, turn OFF the gas. DO NOT OPERATE THE BARBECUE.

Contact Weber-Stephen Customer Service.

b)Valves to manifold connections. Figure 22 (b).

c)Barbecue gas supply line to natural gas supply connection. Figure 22 (c).

mWARNING: If there is a leak at connections b or c, turn OFF the gas. DO NOT OPERATE THE BARBECUE.

Contact Weber-Stephen Customer Service.

When leak checks are complete, turn gas supply OFF and rinse connections with water.

(a)

(b)

(c)

Figure 22

20

Page 20
Image 20
Weber 1500 LX owner manual Check for gas leaks, MWARNING Do not ignite burners while leak checking