Weber 42376 12OPERATING, Liquid Propane Lp Cylinders, Side Burner Lighting Instructions, Danger

Models: 42376 Built In LP Side Burner

1 16
Download 16 pages 58.05 Kb
Page 12
Image 12
12OPERATING

12OPERATING

LIQUID PROPANE (LP) CYLINDER(S)

The joint where the hose connects to the LP cylinder must be leak tested each time the LP cylinder is reconnected. For example, test each time the LP cylinder is refi lled.

Be sure the regulator is mounted with the small vent hole pointed downward so that it will not collect water. This vent should be free of dirt, grease, bugs etc.

The LP cylinder and connections supplied with your Weber® gas barbecue have been designed and tested to meet government, American Gas Association, and Underwriters Laboratories requirements.

(1)

DOT 4BA240

00/02

(2)

If you have questions about spare LP cylinders contact Customer Service at 1-800-446-1071.

All LP tank supply systems must include a collar to protect the cylinder valve.

The LP cylinder must be a 20-lb. size (18 1/4 inches high, 12 1/4 inches in diameter).

The cylinder should be constructed and marked in accordance with the Specifi cations for LP - Gas Cylinders of the U.S. Department of Transportation (D.O.T.) or the National Standard of Canada, CAN/CSA-B339, Cylinders, Spheres and Tubes or Transportation of Dangerous Goods; and Commission, as applicable.

SIDE BURNER LIGHTING INSTRUCTIONS

DANGER

Failure to open the lid while igniting the side burner, or not waiting 5 minutes to allow the gas to clear if the side burner does not light, may result in an explosive flame-up which can cause serious bodily injury or death.

LIGHTING THE SIDE BURNER.

1)Open the side burner lid.

2)Check that the side burner valve is turned OFF. (Push knob in and turn clockwise to ensure that it in the off position.)

WARNING: The burner control knob must be in the OFF position before turning on the liquid propane cylinder valve. If it is not in the OFF position, when you turn on the LP cylinder valve, the “excess gas flow control” feature will activate, limiting the flow of gas from the LP cylinder. If this should occur, turn OFF the LP tank valve and burner control knobs. Then start over.

3)Turn the LP tank valve on (turn counter-clockwise).

4)Push in and turn the side burner control valve to START/HI.

5)Push igniter button and hold until burner ignites. You will hear the igniter sparking.

CAUTION: Side burner flame may be difficult to see on a bright sunny day.

WARNING: If the side burner does not light:



 

LIQUID PROPANE (LP) CYLINDER(S)DOT 4BA240 

1)Turn OFF the side burner control valve.

2)Wait 5 minutes to let the gas clear before you try again or try to light with a match.

TO EXTINGUISH

Push down and turn each burner control knob clockwise to the OFF position. Turn gas supply OFF at the source.

Page 12
Image 12
Weber 42376 12OPERATING, Liquid Propane Lp Cylinders, Side Burner Lighting Instructions, Lighting The Side Burner, Danger