8 | GAS INSTRUCTIONS |
|
|
3). The minimum size of the ventilation hole (s) should not be less than 1/4 inch.
d). The remote LP cylinder enclosure should be constructed with non- combustible materials. The remote LP cylinder enclosure should isolate the LP cylinder from the burner compartment, so that it provides shielding from radiation, be a fl ame barrier and provide protection from foreign material such as hot drippings.
e). There should be a minimum of 2 inches (50.8mm) between the ground and the fl oor of the remote LP cylinder enclosure.
f). The LP cylinder valve should be readily accessible for hand operation. A door on the remote LP cylinder enclosure to gain access to the LP cylinder valve is acceptable, provided it is
If your licensed contractor or licensed plumber builds an LP cylinder enclosure following the guidelines in the ANSI Standard for Outdoor Cooking Gas Appliances,
Z21.58 CSA 1.6, you need to order kit number (#21287), which will contain the hose and regulator assembly, mounting bracket for the regulator, connection
fittings and LP tank bracket for retaining the LP cylinder that must be used with the Summit®
If you do not follow the DANGER statements exactly, the Warranty on the Summit®
CONNECT GAS SUPPLY
1)Uncap the fl are fi tting from the optional side burner connection located
inside the Summit®
Note: We strongly recommend that you use the Summit®
If your, licensed contractor or licensed plumber, builds an LP cylinder enclosure following the guidelines in the ANSI Standard for Outdoor Cooking Gas Appliances,
Z21.58 CSA 1.6, you need to order kit number (#21287).
2)Connect the corrugated gas line to the side burner Connection.
top of box
DANGER
Use of any other hose and regulator assembly could be dangerous, and may not provide adequate gas supply to the Summit®
Plug unused hole with supplied plug.
back of box
90º |
fitting |
Connection to
LP Tank Cap
(Optional Side Burner)
DANGER
Side View
Failure to use the Summit®
Plug unused hole with supplied plug.
back of box
top of box
90º |
fitting |
Connection to
LP Tank
to side burner
Side View