Weber 56576 Maintenance, 71 82, 132 143, m CAUTION The burner openings 12 must be positioned

Models: 56576

1 100
Download 100 pages 27.88 Kb
Page 31
Image 31
71 82 115

MAINTENANCE

Removing The Sear Station® Burner

To remove the Sear Station Burner®, pull the burner tube toward you.. This removes it from the burner tube notch (7).. Then rotate the tube clockwise (8), taking care to rotate the burner tube so that the screw at the end of the tube (9) fits through the notch in the heat shield opening (10). When the burner tube is free, remove it from the firebox (11)..

A) To reinstall the manifold assembly, reverse steps G through I..

71 82 115

m CAUTION: The burner openings (12) must be positioned

 

properly over the valve orifices (13). Make sure the opposite

 

end of the burner tubes (14) properly align into the slots on

93

the backside of the cookbox. Check proper assembly before

 

fastening manifold in place.

 

m WARNING: After reinstalling the gas lines, they should be

104

leak checked with a soap and water solution before using

the grill. (See “CHECK FOR GAS LEAKS”)

 

132 12

143

www.weber.com® 31

Page 31
Image 31
Weber 56576 manual Maintenance, 71 82, 132 143, m CAUTION The burner openings 12 must be positioned