Step 14

Check for gas leaks

m DANGER m

Do not use an open flame to check for gas leaks. Be sure there are no sparks or open flames in the area while you check for leaks. This will result in a fire or explosion which can cause serious bodily injury or death and damage to property.

mWARNING: You should check for gas leaks every time you disconnect and reconnect a gas fitting.

Note - All factory made connections have been thoroughly checked for gas leaks. The burners have been flame tested. As a safety precaution you should recheck all fittings for leaks before using your Weber Genesis Gas Barbecue. Shipping and handling may have loosened or damaged a gas fitting.

mWARNING: Perform these leak checks even though the barbecue was assembled.

You will need: a soap and water solution and a rag or brush to apply it.

Note - Since some leaks test solutions, including soap and water, may be slightly corrosive, all connections should be rinsed with water after checking for leaks.

Make sure side burner is OFF. Remove valve control knob and screws. Remove porcelain top. Figure 22.

mWARNING: Do not ignite burners while leak checking.

Check for leaks by wetting the connections with the soap and water solution and watching for bubbles. If bubbles form or if a bubble grows there is a leak.

Check:

a)Hose to manifold connection. Figure 24 (a).

b)Regulator to tank connection. Figure 24 (b).

c)Manifold to side burner hose connection. Figure 24 (c).

mWARNING: If there is a leak at connections a, b or c, retighten the fitting with a wrench and recheck for leaks with soap and water solution.

If a leak persists after retightening the fitting, turn OFF the gas. DO NOT OPERATE THE BARBECUE.

Contact Weber-Stephen Customer Service.

d)Side burner hose to side burner connection. Figure 24 (d).

e)Valves to manifold connections. Figure 24 (e).

f)Hose to regulator connection. Figure 24 (f).

mWARNING: If there is a leak at connections d, e or f, turn OFF the gas. DO NOT OPERATE THE

BARBECUE. Contact Weber-Stephen Customer Service.

When leak checks are complete, turn gas supply OFF at the source and rinse connections with water.

(a)(b)

(c)

Figure 22

To perform leak checks: open tank valve by turning the tank valve handwheel counterclockwise. Figure 23.

(d)

E

(f)

(e)

 

F

 

Figure 23

10

Figure 24

 

Page 10
Image 10
Weber 63601, 3400 LP manual Check for gas leaks, MWARNING Do not ignite burners while leak checking