28MAINTENANCE

28MAINTENANCE

Be careful not to break or disconnect the wires for the control panel lights.

Rest the control panel against the left side of the grill (A) exposing the valves, burners, igniter, and manifold.

8)Remove the two screws that secure the manifold to the cookbox. Pull manifold

assembly out from the manifold frame.

9) Pull the selected burner(s) tube(s) from manifold frame and replace with a new burner tube.

REMOVING THE SEAR STATIONBURNER

To remove the Sear Station Burner, pull the burner tube toward you. This removes it from the burner tube notch (a.). Then rotate the tube clockwise (b.), taking care to rotate the burner tube so that the screw at the end of the tube (d.) fits through the notch in the heat shield opening (e.). When the burner tube is free, remove it from the firebox (c.).

10) To reinstall the manifold assembly, reverse steps 7 through 9.

CAUTION: The burner openings (A) must be positioned properly over the valve orifices (B).

Make sure the opposite end of the burner tubes (C) properly align into the slots on the backside of the cookbox. Check proper assembly before fastening manifold in place.

WARNING: After reinstalling the gas lines, they should be leak checked with a soap and water solution before using the grill. (See, “Check for gas leaks.”)

(A)a. b. c. Manual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background

a. b. c. Manual background

d.

Manual backgroundManual backgrounde.Manual background