Page 44
UTY4422-002 Page 44 of 72
R - Relay Status
S - Settings Status
ST - SETTINGS TABLE
SP - Serial Port Configuration
[page]: This option can have a value of 1 to 8 and is only applicable for the group status report.
Indicates the page to be reported. If omitted, all eight pages are reported and scroll off the
terminal screen.
A.2 CONTROL COMMANDS
Again, these commands are only active when “Local Control” is enabled. They are the
commands by which you may change unit settings.
A.2.1 ABORT
Insert is terminated.
A.2.2 ADDS location settings
location: Value from 1 - 48 indicating location in settings_table. This value is 1-16 for Audio-
only unit, 1-24 for units using labels, and 1-48 otherwise.
settings: See ‘SETTINGS TABLE’ in Appendix C (Page 63).
The settings are added to the settings_table at the specified location. Will also handle data rate
rounding as explained for PERM.
A.2.3 DELS location
location: Value from 1 - 48 indicating location in settings_table.
The entry in the settings_table at the specified location is deleted. Ignored if only one entry in
settings_table.
A.2.4 MUTE [source][source]
source: If no source is specified then video, async data, and all audios are selected. Source can
be in the following style:
V To indicate Video.
A[/string] To indicate Audio. An ‘A’ without the string indicates all audio outputs. The
string which is contiguous, can contain one or more individual audio outputs (1L,
1R, 2L, ...6R), one or more paired audio outputs (1, 2, ...6), or any combination
these. Multiple outputs must be separated by forward slashes.
Mutes the specified outputs. Example: MUTE V A/1L/2/4/6R, mutes the video, audio Port 1
left, Ports 2 and 4 left and right, and audio Port 6 right.