TROUBLESHOOTING

Inspect and tighten all parts each time the weight system is used. Replace any worn parts immediately. The weight system can be cleaned using a damp cloth and mild non-abrasive detergent. Do not use solvents.

TIGHTENING THE CABLES

Woven cable, the type of cable used on the weight system, can stretch slightly when it is first used. If there is slack in the cables before resistance is felt, the cables should be tightened.

 

 

66

Slack can be removed by moving the 90mm Pulley

15

 

(15) to the lower hole in the Long “U”-bracket (57).

 

 

 

Remove the M10 Nylon Locknut (21) and the M10 x

57

 

48mm Bolt (12) from the Cable Trap (66), Pulley, and

 

 

 

“U”-bracket. Re-attach the Pulley and Cable Trap.

 

21

Make sure that the Cable Trap is positioned to

12

3

hold the Cable in place, and that the Cable and

58

Pulley move smoothly.

 

Additional slack can be removed from the cables by

 

23

 

 

tightening the M8 Nylon Locknuts (3) at the end of the

 

 

Long Cable (23) or at the end of the Short Cable (58).

67

3

To do this you may need to remove the Small “U”-

 

 

bracket (67) from the Weight Tube (63) or remove the

63

 

90mm Pulley (15) from the Long “U”-bracket (57).

 

 

 

Make sure that the cables are not too tight, or the

Top Weight (76) will be lifted off the weight stack.

Note: If a cable tends to slip off the pulleys often, the cable may have become twisted. Remove the cable and re-install it.

If the cables need to be replaced, see ORDERING REPLACEMENT PARTS on the back cover of this manual.

16

Page 16
Image 16
Weider 831.159301 user manual Troubleshooting, Tightening the Cables