TROUBLESHOOTING

TROUBLESHOOTING

CLEANING THE BAR GUIDES

Over time, dust may build up on the Crossbar Guides (15), causing a squeaking noise as the resistance system is used. If this occurs, wipe off the Crossbar Guides with a damp cloth and a mild, non-abrasive detergent. Do not use solvents.

ADJUSTING THE RESISTANCE

When the resistance setting changes, the motor will be heard. To prevent damage to the motor, do not pull any of the cables while the resistance setting is changing. If a cable is pulled, the words

RELEASE HANDLES AND READJUST RESIST- ANCE AS DESIRED may appear in the main display on the console.

If this message is displayed repeatedly but no cable is being pulled, there may be too much tension on the Upper Cable (121). Adjust the tension as described below.

To decrease the tension on the Upper Cable (121), turn the two 3/8” x 38mm Tension Screws (117) twice, counterclockwise. Select the desired resistance set- ting. Repeat this step if necessary.

RECALIBRATING THE CONSOLE

To recalibrate the Console (67), first plug in the resist- ance system (see PLUGGING IN THE RESISTANCE SYSTEM on page 17). Then, press and hold the NEXT button and the MOTORIZED WEIGHT ADJUSTMENT + button for five seconds. When the buttons are released, a number will appear in the REPS display. Press the NEXT button again, and then press the MOTORIZED WEIGHT ADJUSTMENT

+button; this will start the recalibration process. This may take a few minutes as the motor moves between the lowest and highest resistance settings. When the motor finishes, unplug the transformer from the 120- volt outlet.

The Console (67) will be recalibrated. Use the resist- ance system as described in the CONSOLE OPERA- TION section, starting on page 17.