GV90+ gas-fired water boiler — User’s Information Manual

User maintenance procedures

Boiler must be serviced and maintained

DAILY

Maintenance

The boiler should be inspected and started annually, at the beginning of the heat- ing season, only by a qualified service technician. In addition, the maintenance and care of the boiler designated on page 5 and explained on the following pages must be performed to assure maximum boiler efficiency and reliability. Failure to service and maintain the boiler and system could result in equipment failure, causing possible severe personal injury, death or substantial property damage.

The following information provides detailed instructions for completing the maintenance items listed in the maintenance schedule, page 5. In addition to this maintenance, the boiler must be serviced and started up at the beginning of each heating season by a qualified service technician.

Check boiler area

To prevent potential of severe personal injury, death or substantial property damage, eliminate all materials discussed below from the boiler vicinity. If con- taminants are found:

Remove products immediately from the area. If they have been there for an ex- tended period, call a qualified service technician to inspect the boiler and vent system for possible damage from acid corrosion.

If products cannot be removed, immediately call a qualified service technician to install an outside combustion air source for the boiler (if not already installed).

1.Combustible/flammable materials — Do not store combustible materials, gasoline or any other flammable vapors or liquids near the boiler. Remove immediately if found.

2.Air contaminants — Products containing chlorine or fluorine, if allowed to contaminate the boiler intake air, will cause acidic condensate in the vent and boiler. This will cause significant damage to the vent and/or boiler if allowed to continue. Read the list of potential materials listed on page 4 of this manual. If any of these products are in the room from which the boiler takes its combustion air, they must be removed immediately or the boiler combustion air must be supplied from outside. See WARNING above.

Check air openings

1.Verify that combustion and ventilation air openings to the boiler room and/or building are open and unobstructed.

2.Verify that boiler vent discharge and air intake are clean and free of obstructions. Remove any debris on the air intake or flue exhaust openings.

Check boiler pressure/temperature gauge

1.Make sure the pressure reading on the boiler pressure/temperature gauge does not exceed 24 psig. Higher pressure may indicate a problem with the expansion tank.

2.Contact a qualified service technician if problem persists.

6

Part number 550-142-055/0411

Page 6
Image 6
Weil-McLain GV90+ manual User maintenance procedures, Daily, Check boiler area, Check air openings

GV90+ specifications

The Weil-McLain GV90+ is a high-efficiency gas boiler designed to meet the heating demands of residential spaces. Renowned for its reliability and superior performance, the GV90+ is ideal for home heating systems that require both efficiency and comfort.

One of the standout features of the GV90+ is its advanced condensing technology. This allows the boiler to recycle exhaust gases, extracting additional heat and maximizing energy usage. With an impressive Annual Fuel Utilization Efficiency (AFUE) rating of up to 90%, the GV90+ significantly reduces energy consumption, lowering heating bills while minimizing environmental impact.

The GV90+ also boasts a versatile design that can be integrated into a variety of heating systems. It is suitable for both hydronic heating applications and combination systems that provide domestic hot water. This adaptability makes it a popular choice for homeowners looking to enhance their existing heating setup or those building new homes.

Built with durability in mind, the GV90+ features a cast aluminum heat exchanger that is not only lightweight but also highly resistant to corrosion. This construction ensures longevity and reduces maintenance needs, thereby providing peace of mind for homeowners. The boiler's compact size further facilitates installation in tight spaces, making it a convenient solution for both new installations and replacements.

The GV90+ is equipped with an intuitive control system that simplifies operation. The integrated electronic ignition removes the need for a standing pilot, enhancing safety and improving reliability. This smart control technology also allows for precise temperature management, ensuring optimal comfort without unnecessary energy consumption.

Another highlight of the GV90+ is its whisper-quiet operation. Designed to minimize noise, this boiler allows homeowners to enjoy a warm and cozy environment without disruptive sounds. Additionally, Weil-McLain has incorporated safety features such as overheat protection and vent safety switches, ensuring the system operates safely within defined parameters.

In conclusion, the Weil-McLain GV90+ sets a high standard in the residential heating market with its exceptional efficiency, innovative technologies, and robust construction. Catering to a range of heating needs, it promises homeowners reliability, comfort, and significant energy savings, making it a wise investment for any home.