WIRING DIAGRAM (continued)
5-GALLON MODELS 1225 and 1226
|
| HOT WATER |
| POWER |
|
| READY LIGHT |
| LIGHT |
|
| (AMBER) |
| (GREEN) |
|
| BLACK | BLACK |
|
|
|
|
| BLACK |
|
| 7 | 7 | 12 ga. |
|
| 15 | ||
THERMOSTAT |
| SCR |
| |
| MODULE |
| ||
9 | BLACK |
|
|
|
|
| A1(+) |
| |
5 | BLACK | T1 | L1 |
|
|
|
|
Dispenser
4 WHITE
WATER
LEVEL
PROBE
11
GREEN
WATER | COMM | |
| ||
LEVEL |
| |
CONTROL | N.O. | |
BOARD | ||
| ||
| N.C. | |
| 3 BLACK | |
MAX |
| |
| INPUT | |
COMM |
|
BLACK 12 ga.
14
TANK
HEATER
SWITCH
2 WHITE
13 BLACK
| HEATING ELEMENT |
| 4000 WATTS |
WHITE | 12ga. |
16 | RED |
|
10
6
RED 12 ga.
WHITE | BLACK | |
8 | ||
|
12
712 76580 Owners Manual Hot Water
240V POWER CORD
NEMA
BLACK
WHITE
MODEL 1225 and 1226
1 WHITE
GREEN
FILL
SOLENOID
17