DANGER:

DANGER:

FIRE AND

EXPLOSION

HAZARD

NEVER use an open flame to check for gas leaks. Fire and explosion may result.

IMPORTANT:

All pipe joints must be checked for leaks before lighting. Leak checks should be performed with a soap and water solution.

FIRE AND FIRE HAZARD WARNING:

Fig. 2 Gas Supply PipingManual background FIRE HAZARD

This hotplate is supplied with a gas pressure regulator. Failure to properly install the supplied regulator will result in an extremely hazardous condition.

Flow arrow stamped on body of regulator must point toward the hotplate.

Regulator adjusting screw and vent hole must point UP.

IMPORTANT:

Verify fuel gas type. If the available fuel does not match the nameplate specification, exchange the hotplate for the correct type. DO NOT attempt to modify a unit in the field to accept a different fuel.

IMPORTANT:

Avoid damage to the regulator: if the gas supply piping system is pressure tested at pressures exceeding 1/2 psig (3.45kPa) , the hotplate must be isolated or disconnected from the gas piping system for the duration of the test.