SYMPTOM

SYMPTOM

POSSIBLE CAUSE

SUGGESTED REMEDY

 

 

 

 

Circuit breaker off or tripped

Reset circuit breaker

No power to warmer

 

 

Unit not plugged in

Make sure unit is plugged in to

 

 

power receptacle

 

 

 

 

 

 

Temperature control not set

Set control to desired

 

temperature

Warmer will not heat

 

 

 

Internal damage

Contact you Authorized Wells

 

 

Service Agency for repairs

 

 

 

 

 

 

Wet insulation

Allow to dry or replace insulation

 

 

 

Warmer trips circuit breaker

Pan leaking or other internal

Contact your Authorized Wells

damage

Service Agency for repairs

 

 

 

 

 

Internal damage

Contact your Authorized Wells

 

Service Agency for repairs

 

 

 

 

 

 

Mineral deposits on pan acting

Clean pan(s) with delime

 

cleaner. DO NOT USE ON

 

as a insulator

 

ALUMINUM SURFACES!

 

 

 

 

 

Warmer slow to heat

 

Verify supply voltage (must

Connected to wrong voltage

match voltage on warmer

 

 

 

nameplate)

 

 

 

 

Too much water in pan

Remove water from pan until 1”

 

of water remains in pan

 

 