SYMPTOM | POSSIBLE CAUSE | SUGGESTED REMEDY | |
|
|
| |
| Circuit breaker off or tripped | Reset circuit breaker | |
No power to warmer |
|
| |
Unit not plugged in | Make sure unit is plugged in to | ||
| |||
| power receptacle | ||
|
| ||
|
|
| |
| Temperature control not set | Set control to desired | |
| temperature | ||
Warmer will not heat |
| ||
|
| ||
Internal damage | Contact you Authorized Wells | ||
| |||
| Service Agency for repairs | ||
|
| ||
|
|
| |
| Wet insulation | Allow to dry or replace insulation | |
|
|
| |
Warmer trips circuit breaker | Pan leaking or other internal | Contact your Authorized Wells | |
damage | Service Agency for repairs | ||
| |||
|
|
| |
| Internal damage | Contact your Authorized Wells | |
| Service Agency for repairs | ||
|
| ||
|
|
| |
| Mineral deposits on pan acting | Clean pan(s) with delime | |
| cleaner. DO NOT USE ON | ||
| as a insulator | ||
| ALUMINUM SURFACES! | ||
|
| ||
|
|
| |
Warmer slow to heat |
| Verify supply voltage (must | |
Connected to wrong voltage | match voltage on warmer | ||
| |||
|
| nameplate) | |
|
|
| |
| Too much water in pan | Remove water from pan until 1” | |
| of water remains in pan | ||
|
|
There are no