SYMPTOM | POSSIBLE CAUSE | SUGGESTED REMEDY | |
|
|
| |
No power to warmer | Circuit breaker off or tripped | Reset circuit breaker | |
|
|
| |
Warmer will not heat | Temperature control not set | Set control to desired | |
temperature | |||
|
| ||
|
| Verify | |
| Wet insulation | sound, or reseal with | |
|
| silicone sealant | |
Warmer trips circuit breaker | Pan leaking or other internal | Contact your Authorized Wells | |
| damage | Service Agency for repairs | |
| Internal damage | Contact your Authorized Wells | |
| Service Agency for repairs | ||
|
| ||
| Mineral deposits on pan acting | Clean pan(s) with delime cleaner | |
| as a insulator | ||
|
| ||
Warmer slow to heat |
|
| |
| Verify supply voltage - must | ||
| Wired to wrong voltage | match voltage on warmer | |
|
| nameplate | |
| Drain valve not fully closed | Check drain valve for debris and | |
close fully | |||
water | Drain valve damaged or pan(s) | Contact your Authorized Wells | |
| leaking | Service Agency for repairs | |
|
|
| |
| Water level sensor dirty | Clean water level sensor | |
|
| ||
Internal damage | Contact your Authorized Wells | ||
| |||
| Service Agency for repairs | ||
|
| ||
|
|
| |
| Water supply turned off or | Be sure water supply is turned | |
| on and water supply hose is not | ||
| restricted | ||
pinched or twisted | |||
| |||
| Bad Probe or other Internal | Contact your Authorized Wells | |
| Damage | Service Agency for repairs | |
One or more pans of an | Blocked drain manifold | Clean drain manifold | |
unit do not fill |
|
|
There are no
In all instances of damage or malfunction, contact your Authorized Wells Service Agency for repairs.
011 303308 OpManual for
10