![MAINTENANCE INSTRUCTIONS](/images/new-backgrounds/57394/5739419x1.webp)
MAINTENANCE INSTRUCTIONS
CAUTION:
INJURY HAZARD
Disconnect appliance from electrical power before performing any of these procedures.
Adjust Positioning Cam
CAUTION:
BURN HAZARD
Lamp may be hot.
Allow lamp to cool before replacing.
ADJUST STIRRER NEUTRAL POSITION
With the kettle switch OFF, the stirrer should land at a position that allows the kettle to rotate without binding on the stirrer wand. If the stirrer wand does not land positioned left to right, adjust the positioning cam:
1.Disconnect unit from electric power. Remove the top panel. Raise the kettle lid until it is captured by the magnetic holder.
2.Spin the gearmotor fan by hand until the stirrer wand is positioned left to right (I.e. parallel to the front of the cabinet).
3.Loosen the positioning cam nut and locknut. Turn the cam until it depresses the pin of the positioning switch. Tighten the cam nut and lock nut.
4.Reconnect unit to electric power. Press the kettle switch to “ON”. Wait approximately 5 seconds, then press the kettle switch to “OFF”. The stirrer motor will run until the positioning cam activated the positioning switch.
5.If the stirrer wand stops in the proper
CHANGE HEAT LAMP
1.Press warmer switch “OFF”. Allow unit to cool before replacing lamp.
2.Squeeze front and rear portions of guard until the front hook clears the slot. Slide the rear hook from its slot, then remove the guard.
3.Unthread old heat lamp from its socket and discard.
4.Thread new heat lamp into socket.
IMPORTANT: Use only 400W
5.Reinstall guard.
232 306223 Owners Manual
Change Heat Lamp
8