OPERATION

CAUTION:

HOT SURFACE

Exposed surfaces can be hot to the touch and may cause burns.

Fig. 10 Ventilator Indicator and Warning Lights

VENTILATOR OPERATION

1.Press the VENTILATOR POWER switch to ON. The green VENTILATOR POWER light will glow and the blower fan will start. After a short time, if all filters are sensed as being in position and not clogged, the cooking appliance will be energized.

During normal operation, the VENTILATOR POWER light will be the only light glowing on the upper control panel.

2.If the amber CHECK FILTER light glows, one or more filter elements is out of position. Check the GREASE BAFFLE, PRE-FILTER and FILTER PACK for proper installation in their respective positions. Grease baffle and filter pack position are sensed by mechanical switches. Pre-filter position is sensed by a vacuum switch.

3.When the amber REPLACE PRE-FILTERlight glows, the pre-filter is nearing the end of its service life. Replace the disposable

PRE-FILTER ELEMENT.

4.When the amber REPLACE FILTER PACK light illuminates, the HEPA / Charcoal filter pack is nearing the end of its service life. Replace the FILTER PACK.

Note: The REPLACE PRE-FILTER and REPLACE FILTER PACK lights are a warning that the indicated filter is near the end of its service life. The appliance will continue to operate for a period of time after the light glows to allow continued operation through a peak period. However, the indicated filters must be replaced within a reasonably short time period or they will clog and shut down electrical power to the cooking appliance . The ventilator blower will continue to run.

5.When the red SERVICE REQUIRED light glows, either the pre-filter or filter pack (or both) is clogged and can no longer pass sufficient air to allow further operation. The ventilator fan continues to run, but the cooking appliance is shut down until the underlying clogged filter situation has been corrected. This can occur when neither CHANGE...FILTER indicator light is lit, if both pre-filter and filter pack are marginal. Replacing both the pre-filter and the filter pack will remedy the situation.

Note: Replacing the pre-filter, even though not very dirty, will often extend the service life of the more expensive filter pack.

Reset the unit by turning the VENTILATOR POWER switch to OFF, then back ON.

6.A failure of incoming electrical power will cause a shut down of the unit. After power is restored, reset the unit by turning the VENTILATOR POWER switch to OFF, then back ON.

NOTE: Griddle and fryer will not operate unless the fire suppression system is charged, and the ventilator section is operating .

16

Page 18
Image 18
Wells WV-FGRW operation manual Ventilator Operation, PRE-FILTER Element

WV-FGRW specifications

Wells WV-FGRW is a prominent and innovative water treatment solution designed to meet the evolving demands of water quality and conservation. This state-of-the-art facility is a paradigm of modern engineering, leveraging advanced technologies to ensure that residents and industries alike receive clean, safe, and reliable water supply.

One of the standout features of Wells WV-FGRW is its use of cutting-edge filtration systems. These systems employ multiple stages of filtration, including sand, activated carbon, and membrane filtration, to effectively remove contaminants such as sediments, chemicals, and biological pathogens. This multi-barrier approach not only enhances water purity but also improves the overall taste and odor of the water.

Additionally, the facility integrates real-time monitoring technologies, utilizing sensors and automated data analysis to track water quality parameters continuously. This enables the staff to respond promptly to any fluctuations in water quality, ensuring a swift resolution to potential issues. Such proactive management significantly reduces the risks linked to waterborne diseases and maintains regulatory compliance.

Wells WV-FGRW is also designed with sustainability in mind. Energy-efficient technologies power the treatment processes, minimizing the ecological footprint. Solar panels and other renewable energy sources contribute to a significant portion of the operational energy needs, demonstrating a commitment to environmental stewardship.

Furthermore, the facility employs an advanced chemical dosing system to effectively manage disinfection processes. Utilizing technologies like ultraviolet (UV) light and ozone treatment, the facility achieves an efficient, non-toxic method of disinfecting water, reducing reliance on harsh chemicals.

Another key characteristic of Wells WV-FGRW is its commitment to community involvement and education. The facility frequently conducts workshops and tours for local schools and organizations to raise awareness about water conservation and the importance of maintaining clean water sources.

In conclusion, Wells WV-FGRW exemplifies excellence in water treatment, showcasing an array of modern technologies and a firm dedication to sustainability and community engagement. With its innovative approach to managing water resources, the facility stands as a vital asset for the local community, ensuring a safe and reliable water supply for generations to come.