Wells WVPE-30F, WVAE-30F, WVAE-55FS operation manual Danger

Models: WVPE-30F WVAE-55FS WVAE-30F WVAE-55F

1 22
Download 22 pages 467 b
Page 11
Image 11
DANGER

M381 301603 OpM (Supplemental) NFPA Hood

 

IMPORTANT!

 

VACUUM FITTING

280ºF

DO NOT INSTALL

DISCHARGE NOZZLE

FUSIBLE LINK

HERE!

 

DISCHARGE

NOZZLES

INSIDE OF HOOD

LOOKING UP

INSTALL ON LEFT OR

INSTALL ON RIGHT

SIDE OF HOOD

SIDE OF HOOD

BACK, HORIZ.,

BACK, HORIZ.,

LEFT SIDE,

RIGHT SIDE

INSTALL (8-1/4”)

INSTALL (5-3/4”)

CENTER,

 

VERT. 3”

 

SIDE, VERT. (6”) Manual backgroundManual background

SIDE, HORIZ. (13-1/2”)

MANUAL PULL

STATION PIPING

FRYPOT

FUSIBLE LINK

NOTE

CABLE

ROUTED

UNDER

Manual background GUIDE

CRIMP

FERRULE

CLIP

450ºF

FUSIBLE LINK

HEATSINK

DANGER

BURN HAZARD

HOT OIL SPILL

Any additional remote pull station must not be installed on the front or sides of the fryer forward of the ventilator side panels.

Discharge of the fire extinguishing system into hot oil will cause hot foam to spill over from the frypot. Serious burns and other injuries can result from contact with hot oil and from slipping in spilled oil.

Exclusive Anti-Fire System In the unlikely event that both the temperature control thermostat and hi-limit detector fail, and the oil temperature climbs above the safety limit, the fire suppression system will discharge, cooling the oil below the oil’s (approximately) 540ºF auto-ignition temperature, and preventing a fire from occurring.