Weslo 831.29462 Maintenance and TROUBLE-SHOOTING, Circuit breaker located on Treadmill, Top View

Models: 831.29462

1 18
Download 18 pages 16.77 Kb
Page 12
Image 12

MAINTENANCE AND TROUBLE-SHOOTING

Most treadmill problems can be solved by following the simple steps below. Find the symptom that applies and follow the steps listed. If further assistance Is needed, call our toll-free HELPLINE at 1-800-736-6879, Monday through Saturday, 7 a.m. until 7 p.m. Central Time (excluding holidays).

PROBLEM: The power does not turn on

SOLUTION: a. Make sure that the power cord is plugged into a surge suppressor, and that the surge suppres-

sor is plugged into a properly grounded outlet (see page 7). Use only a single-outlet surge sup- pressor that is UL 1449 listed as a transient voltage surge suppressor (TVSS). The surge sup- pressor must have a UL suppressed voltage rating of 400 volts or less and a minimum surge dissipation of 450 joules. The surge suppressor must be electrically rated for 120 volts AC and 15 amps. Important: The treadmill is not compatible with GFCl-equipped outlets.

b. After the power cord has been plugged in, make sure that the key is fully inserted into the console.

frame

near the power cord.

If the switch

pro-

c

 

trudes

as shown, the circuit

breaker has

tdpped.

Tripped

Reset

To reset the circuit breaker, wait for five minutes

II

I_

c. Check

the circuit breaker located on the

treadmill

and then press the switch back in.

 

 

 

PROBLEM: The power turns off during use

SOLUTION: a. Check the circuit breaker located on the treadmill frame near the power cord (see the drawing above). If the circuit breaker has tripped, wait for five minutes and then press the switch back in.

b. Make sure that the power cord is plugged in.

c. Unplug the power cord, wait for five minutes, and then plug the power cord back in.

d. Remove the key from the console. Reinsert the key fully into the console.

e. If the treadmill still will not run, please call our toll-free HELPLINE.

PROBLEM: The displays of the console do not function properly

SOLUTION: a. Check the batteries in the console. If the batteries need to be replaced, see BATTERY INSTALLATION on page 8. Most problems are the result of drained batteries.

b. Remove the key from the console and UNPLUG THE POWER CORD. Remove the screws from the

hood. Carefully remove the hood. Locate the Reed

Switch (76) and the Magnet (47) on the left side of the Pulley (77). Turn the Pulley until the Magnet is aligned with the Reed Switch. Make sure that the gap between the Magnet and the Reed Switch is about 1/8". If necessary, loosen the Screw (17) and move the Reed Switch slightly. Retighten the Screw. Re-attach the hood, and run the treadmill for a few minutes to check for a correct speed reading.

IOI77

/

17_ cC

76---__7 1/8"--

Top View

12

Page 12
Image 12
Weslo 831.29462 user manual Maintenance and TROUBLE-SHOOTING, Circuit breaker located on Treadmill, Top View