5.SYMPTOM: THE WALKING BELT IS OFF-CENTER

a.If the walking belt has shifted to the left, first remove the key and UNPLUG THE POWER CORD. Using the allen wrench, turn the rear roller adjustment bolt clockwise 1/4 of a turn. Plug in the power cord, insert the key and run the treadmill for a few min- utes. Repeat until the walking belt is centered.

b.If the walking belt has shifted to the right, first remove the key and UNPLUG THE POWER CORD. Using the allen wrench, turn the rear roller adjustment bolt counterclockwise 1/4 of a turn. Plug in the power cord, insert the key and run the treadmill for a few minutes. Repeat until the walking belt is centered.

STORAGE

Unplug the power cord when the treadmill is not in use.

Remove the bolt and nut from the lower end of each handrail.

Remove the bolt from the upper end of each handrail.

Remove the bolt and washer from the lower end of the upright. Lay the upright on the treadmill. Keep all bolts and washers in a secure location.

Remove the batteries from the console and cover the treadmill dur- ing extended periods of storage.

a

b

Remove

Remove

Remove

11

Page 11
Image 11
Weslo WCTL39102 user manual Symptom the Walking Belt is OFF-CENTER, Storage