b.If the walking belt slips when walked on, first remove the key and UNPLUG THE POWER CORD. Using the hex key, turn both idler roller screws clockwise, 1/4 of a turn. When the walk- ing belt is correctly tightened, you should be able to lift each edge of the walking belt 2 to 3 in. (5 to 7 cm) off the walking platform. Be careful to keep the walking belt centered. Then, plug in the power cord, insert the key, and carefully walk on the treadmill for a few minutes. Repeat until the walk- ing belt is properly tightened.

b

SYMPTOM: The upperbody arms squeak during use

a.(Note: Correcting this problem requires a small amount of white marine grease, available at hardware stores.) Turn the Resistance Knob (A) counterclockwise and remove it. Next, remove the Resistance Cone (B) and the Left Upper Body Arm (105), along with the Resistance Plate (C), Washers (D), Spring Washer (E), Thrust Washers (F), and Thrust Bearing (G). (Note: If the Resistance Plate [C] comes out of the Resistance Cone [B], press it back in.) Apply a thin layer of white marine grease to the outer surface of the Resistance Cone (B). Then, reattach all parts in the order shown below.

a

B

105

 

 

 

 

F

 

 

E

A

 

 

C

G D

 

 

 

20

Page 20
Image 20
Weslo WLTL31312.0 user manual 105