RMM User’s Guide
Command | Function/Options | |
&Tn | Begins test modes. | |
| &T0 | Ends Test in Progress |
| &T1 | Analog Loopback |
| &T2 | Reserved |
| &T3 | Local Digital Loopback |
| &T4 | Enables Remote Digital Loopback |
| * &T5 | Prohibits Remote Digital Loopback |
| &T6 | Initiates Remote Digital Loopback |
| &T7 | Remote Digital with self test and |
|
| error detector |
| &T8 | Analog Loopback with self test and |
|
| error detector |
$Un | Sets floor connect speed when &Un is greater than 0. | |
| &Nn is the ceiling connect speed (See &Nn). | |
| * &U0 | Disabled |
| &U1 | 300 bps |
| &U2 | 1200 bps |
| &U3 | 2400 bps |
| &U4 | 4800 bps |
| &U5 | 7200 bps |
| &U6 | 9600 bps |
| &U7 | 12,000 bps |
| &U8 | 14,400 bps |
| &U9 | 16,800 bps |
| &U10 | 19,200 bps |
| &U11 | 21,600 bps |
| &U12 | 24,000 bps |
| &U13 | 26,400 bps |
| &U14 | 28,800 bps |
| &U15 | 31,200 bps |
| &U16 | 33,600 bps |
&Wn | Writes current configuration to NVRAM templates. | |
| &W0 | Modifies the NVRAM 0 template (Y0) |
| &W1 | Modifies the NVRAM 1 template (Y1) |
&Yn | Sets break handling. | |
| &Y0 | Destructive, but doesn't send break |
| * &Y1 | Destructive, expedited |
| &Y2 |
Page 14