Important Installation and Utility Information
Electrical Service:
110V: 110V, 60 Hz, 2.75 A mp GFCI protected grounded circuit must be used to supply pow er to the pedicure spa. (220V if ordered in 220V configuration)
220V: 220V, 50/60 Hz, 2.75 Amp GFCI protected grounded circuit must be used to supply pow er to the pedicure spa.
Water Supply:
All plumbing connections must conform to local codes.
Normal w ater pressure of 30 to 80 PSI is required to correctly fill the basin to the proper level.
Maximum operating w ater temperature should not exceed 105° F (41° C) and the maximum supply water
temperature should not exceed 150° F (65° C). (In Massachusetts, the maximum supply water temperature
should not exceed 130° F (54° C)). Adjust your hot water heater accordingly.
For hot and cold w ater supply fittings and pow er drain fittings location, see figure 1 below .
Carefully connect the incoming w ater supply lines to the appropriate fittings located on the back of the pedicure spa.
The pedicure spa drain must meet local plumbing codes. Check valve for drain are not provided and must be installed by a licensed plumber, if required by Local or State codes.
**Note: See local and state codes as to what type of drain connection is required to be made.
Plumbing ConnectionsHot & Cold supply fittings contain Neoperl® DW15GF check valves. See figure 1 for proper flow direction.
(does not hav e c heck v alve)
Back of Pedicure Spa
Figure 1
Note: Not using the supplied bulkhead fittings will result in NO backflow protection. Check your Local & State plumbing codes for additional backflow requirements.
Backflow Protection Devices for Faucets with Side Spray: Check valves comply with ANSI/ASME A112.18.3M, A112.18.1M, CSA B125, and NSF 61
ANSI/ASME A112.18.3M (Performance Requirements for Backflow Protection Devices and Systems in Plumbing Fixture Fittings) is applicable to plumbing fixture fittings w ith outlets not protected by an air gap. Included in the possible range of applications are fittings with hose connected outlets, fittings w ith pullout spout, hand held show ers, shampoo fittings and
ANSI - American National Standards Institute
ASME - American Society of Mechanical Engineers
CSA - Canadian Standards Association
IAPMO - International Association of Plumbing and Mechanical Officials
UL - Underwriters Laboratory
TÜV - Technischer