Proper installation is your responsibility. Make sure you have everything necessary for correct installation. It is the responsibility of the installer to comply with the installation clearances specified on the model/serial rating plate. The model/serial rating plate can be found on the bottom of the cooktop.
Check location where cooktop will be installed. The location should be away from strong draft areas, such as windows, doors and strong heating vents or fans. The cooktop should be located for convenient use in the kitchen.
When installing a cooktop under existing cabinets and the installation does not meet the minimum cabinet clearances, install a range hood above the cooktop to avoid burn hazards.
ALL OPENINGS IN THE WALL OR FLOOR WHERE THE COOKTOP IS TO BE INSTALLED MUST BE SEALED.
Do Not obstruct the flow of combustion and ventilation air.
Grounded electrical outlet is required. See “Electrical requirements.”
Proper gas supply connection must be available. See “Gassupply requirements.”
Countertop opening dimensions that are shown mustbe used. Given dimensions provide required 0” (0 cm) clearance.
Important: Observe all governing codes and ordinances. Failure to meet codes and ordinances could lead to fire or electric shock.
Your safety and the safety of others is very important.
We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety messages.
This is the safety alert symbol. This
!symbol alerts you to hazards that can
0kill or hurt you and others. All safety messages will be preceded by the safety alert symbol and the word “DANGER”or “WARNING”.These words mean:
You will be killed or seriously injured if you don’t follow instructions.
| | | | | | | | | | |
Cabinet | dimensions | 30” | (76.2 | cm) cooktop | - 30” | (76.2 | cm) | |
| | min. | cabinet | width | above cooktop | | |
| | 36” | (91.4 | cm) cooktop | - 36” | (91.4 | cm) | d |
| | min. | cabinet | width | above cooktop | | |
13” (33.0 cm)
max. - upper
for minimum
You can be killed or seriously injured if you don’t follow instructions.
All safety messages will identify the hazard, tell you how to reduce the chance of injury, and tell you what can happen if the instructions are not followed.
WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property
damage, personal injury or death.
2-112”
(6.4 cm) burner box height
***Note: 30” (76.2 cm) min. when bottom of wood or metal cabinet is protected by not less than 114” (.6 cm) flame retardant millboard covered with not less than No. 26 MSG sheet steel, 0.015” (.04 cm) stainless steel, 0.024” (.06 cm) aluminum or 0.020” (.05 cm) copper.
36” (91.4 cm) min. clearance between the top of the cooking platform and the bottom of an unprotected wood or metal sheet.
| | | | 36” | (91.4 cm) |
| | | | cooktop - | |
| | | | 1” (2.5 cm) | |
| | 15” | (36.1 cm) | min. space | to |
Wall ‘gas | line | front | edge | of |
opening | - 5” | max. | from | countertop | |
(12.7 cm) | below | bottom of | | | |
countertop | | | |
countertop | and | | | |
| | | | |
power supply cord between the cooktop and cabinet.
- Do not store or use gasoline or |
other | flammable | vapors | and |
liquids in the vicinity of this or |
any | other | appliance. | |
- WHAT TO DO IF YOU SMELL |
GAS | | | | | |
l Do not try to light any | |
appliance. | | | |
l Do not touch any electrical |
switch. | | | | |
l Do not use any phone in your |
building. | | | | |
l Immediately | call your gas |
supplier | from | a neighbor’s |
phone. | Follow | the gas | |
supplier’s | | instructions. | |
l If you cannot reach your |
gas supplier, call the fire |
department. | | | |
- Installation | | and | service | must |
Cutout dimensions
I’B‘I
| | ---c- | . | ---- |
| | | ., | - |
| | A | | l . |
| | | l . |
| | | |
| | | | l . . |
‘\ \ | | | | |
\ | \ | | | |
| L---D | && | | D |
Minimum distance to nearest side combustible surface above cooktop.
cutout:
A | depth | | 16-3/Y | | 16-3/4” | |
| | | (47.6 cm) min. (47.6 cm) min |
B | width | | 26-l R” | | 33” | |
| | | (67.3 cm) min. (63.6 cm) min. |
c fyp~~to2-5ia~~ | min. | 2-5W | min. |
| nearest | rear | (6.7 cm) | (6.7 cm) |
| | | | |
| combustible | | | | |
| surface | | | | | |
| above | | | | | |
| cooktop. | | | | | |
DM inimum | to | 5-114” | min. | S-114” | min, |
| distance | (13.3 cm) | (13.3 cm) |
| nearest | side | | | | |
combustible surface above COOktOD.
| | | |
be performed | by | a qualified |
installer, | service | agency or |
the gas | supplier. | |
It is the customer’s responsibility:
l To contact a qualified electrical installer. l To assure that electrical installation is
adequate and in conformance with National Electrical Code, ANSUNFPA
70 - latest edition* and all local codes and ordinances.
Mobile home installation
The installation of this cooktop must conform to the Manufactured Home Construction and Safety Standards, Title 24 CFR, Part 3280 (formerly the Federal Standard for Mobile Home Construction and Safety, Title 24, HUD Part 280); or when such standard is not
Product dimensions
30” (76.2 cm)
cooktop
30” (76.2 cm) min. base cabinet is required. If cabinet has a drawer, a
3-l/2” (8.9 cm) depth clearance from the countertop to the top of the drawer (or other obstruction) in base cabinet is required.
36” (91.4 cm) min. base cabinet is required. If cabinet has a drawer, a
3-l/2” (8.9 cm) depth clearance from the countertop to the top of the drawer (or other obstruction) in base cabinet is required.
GrilUgriddle cooktop must be used with suitable vent hoods.
applicable, the Standard for Manufactured Home Installation 1982 (Manufactured Home Sites, Communities and Setups), ANSI A225.1/NFPA 501A - 1987, or latest edition, or with local codes.
Copies of the standards listed may be obtained from: l National Fire Protection Association
Batterymarch Park
Quincy, Massachusetts 02269
l * American Gas Association
1515 Wilson Boulevard
Arlington, Virginia 2,2209