Whirlpool 4.32E+13 Before you start, Cabinet di, dimensions JFj, Example RC8536, 19- l/2” cutout

Models: 4.32E+13

1 7
Download 7 pages 18.28 Kb
Page 2
Image 2
Cabinet di

Cabinet di

A

= cabinet

wall

 

to

rear

line

of

A

cutout

 

 

 

 

 

Allow

 

l/2”

from

L

rear

of

downdraft

 

vent

to back wall

T

of

cabinet.

 

 

Left cabinet wall cutout: Centerline is 17-3/16” from countertop.

\

Use dimensions \ for ductwork

cutout location that applies to your installation.

 

See cooktop

Cutout width:

manufacturer’s

instructions for

30” vent-27-l/2”

 

rear edge of cooktop overlaps edge of downdraft vent by J/8”.

Locate power supply junction box at lower right corner of cabinet.

Before you start...

Important: Observe all governing codes and ordinances. Failure to meet codes and ordinances could lead to fire or electrical shock.

Proper installation is your responsibility. Make sure you have everything necessary for correct installation. It is the responsibility of the installer to comply with the installation clearances specified on the model/serial rating plate. The model/serial rating plate is located on the front of the downdraft vent above the wiring box cover.

Check location where retractable

downdraft vent will be installed. The location should be away from strong draft areas, such as windows, doors and strong heating vents or fans. Before making countertop cutout, check that retractable downdraft vent and cooktop location will clear cabinet walls, backsplash, and rear wall studs inside cabinet.

ALL OPENINGS IN THE WALL OR FLOOR WHERE RETRACTABLE DOWNDRAFT VENT IS TO BE INSTALLED MUST BE SEALED.

Electrical ground is required. See “Electrical requirements, I Panel B.

cutout

l-

x---d

dimensions JF)j

Figure 1

Dimension A: If just a “Max.” dimension is given, that dimension must be used.

*If dimension A is between the “Min.” and “Max.“:Subtract actual dimension “A” from ‘A Max. y Divide by 2.

Add to ‘B (for A Max.)” for required

Bdimension.

Models

Jt -i+

C

Figure 2

Example: RC8536, 19- l/2” cutout

“AMax.”

20-l /4”

 

Actual

“A”

-

19-l/2”

 

 

 

 

314”

+ 2 = 318

B (for

A Max.)

 

2-l/2”

 

 

 

+

3ian

 

 

 

 

2-7/8”

= Required B

 

 

 

 

dimension

When installing retractable downdraft vent, the cabinet drawer will need to be removed and the drawer front installed permanently to cabinet.

30” min. base cabinet is required. If cabinet has a drawer, 3-l/2” depth clearance from the countertop to the top of the drawer (or other obstruction in the base cabinet) is required.

Note: Retractable downdraft vent is installed directly behind the cooktop. Install retractable downdraft vent first.

This appliance is not approved for use in mobile homes.

Cabinet construction: This appliance is designed for use in a cabinet with a depth of 24 inches. The maximum depth of the overhead cabinet is 13 inches. Overhead cabinets installed at either side of the appliance must be 18 inches above the cooking surface. See cooktop Installation Instructions for the minimum distance between the front edge of the countertop and front edge of cooktop. The minimum horizontal distance between the overhead cabinets is the same as the width of the installed appliance.

C8200XY/RC8400XY/

k84ooXYQ RC8536XT *

RC8600XXB/Q

8’.-“‘“” RC8436XT/RC8436XTW *

RC8330XTB/RC8430XT/ ] RC8430XTW l

SC8630EX and EAW/N/B/Q

SC8430ERbC8430ERH

SC8536EX/SC8536EXH/

SC&36EXB/SC8536EXQ

[i#ii$$&iijiiiFj ::.::::$g.fg:::::::::::::I

.........................

:,::...: .ii.. i::ii::~:i:jiiiij 1 ;..:

:iii:!! 1

.A...:...........

.........

+ziiis

..........:::x:;:;:::.:.:.:.:

: : :i

,::.:J@..:, $i’i’i’ 1

....:.:.:.:.:

.>:.:: .,.,.,.,.:.:.:.:,:.:.:.

...................,,...:

s @:jZ 2 ;iiiip

:~~

 

 

19-l 14”

~~~

 

p-5/8”

 

 

.,...,

 

 

 

...........................

i.ifiii~~~~~~~iiiiil:27-,/p”

.,

...........~

 

:::::::::::::::::~:~:::::~:~:~:~:~:

:j:j:~

......

~

iiiiiiiiaiis~~~

 

li;i;i;i;i;i;i;i::;i;i;i;j;i;i;i;i;:33- , ,2”

,:::::Jz@“.n..

20- 1/4”

 

:.:..:..;::::&gg$

::::::::,%:;,:: _.,,...., ,,.

2- 1/ 2”

i:::::::~:::::~:~:~:~:~:~:~:~:~:~:~

::::::::::::::::::::::::::::::::::::::::::

iiijiiijiiijjiijijijjijijjijiiijijjjjjij~PO-1/4”

iiiliiilililiiiiililii:i:i;:i:i:l:i:i:l:~:~~~~.:,:,~~:. .~:,~:,::::::::::j:j:j:j:j:j:~:~~:~ii~:

 

27-11~

..... ..........

 

 

. .A....

 

2- 118”

.................................

 

 

 

.....,.,..,,,,,..,,..,,.,.

33-l/2”

...iiiBig3:~.,.,.,&3?.,,,.~.“,&..~.~.,20.-5/8”

~~~P~~~

2-5/1(fy

~

 

 

 

...,...,

 

 

 

 

:i:i:i:i:i:i:i:i:~:i:i:i:i:i:i:i:i:i

:::::...................,:,.... :...::.....~,

~~~~~

 

 

$4 ..

::i:i: 2&5,8”

2-5/l 6”

~

 

 

27-1,2~~

:.i~~~~~~~~~

 

 

 

 

 

 

3i:~:~:~~~~~~~~~~~~~~~~~:~:~~~:~:~~~:~~:~~~~::

.:.:.....:...:

 

 

 

 

 

:..:...

,.......,.,.

 

 

:::

 

:,:.:.:.:::::::::::::::::j::::::::::::::::,Q’ ~~~~~~~~~~~

 

 

 

 

 

.,....................................:::::::

 

:.:.>>>>:.,.,...,.,.,>:.,.,:.,:.,:.,.,.l-314”

iiidi%d~~Sjiii:l27- l/y

,.

. ...,.....,.

 

 

 

 

WARNING - TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:

A. Installation Work And Electrical Wiring

Must Be Done By Qualified Person(s) In

Accordance With All Applicable Codes

And Standards, Including Fire-Rated

Construction.

30” vent width - 26-518”

Retractable downdraft36” vent width - 32-518”vent dimensions

114” tractable mt height

I3O’vent base width - 27” 36” vent base width - 3T

B. The combustion airflow needed for safe operation of fuel-burning equipment may be affected by this unit’s operation.

Follow the heating equipment manufacturer’s guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities.

C. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.

D. Ducted fans must always be vented to the outdoors.

E. If this unit is to be installed over a tub or shower, it must be marked as appropriate for the application.

26

: