GENERAL | INFORMATION |
|
|
|
|
| |
l UNPACK | 2 | Either | a gravity drain | system | or a sump pump | to flft | |
|
| the water to an exrsting drain. |
|
|
| ||
| 3 | An electrical branch | clrcult | of 115 | Volt, 60 | Hz. 1 | |
|
| phase, | with a 15 Amp | delayed | actron | fuse. |
|
. LOCATE UNIT
INTERIOR
PACKING
OPEN BOTTOM FLAPS
FIGURE | 3 | FIGURE | 4 |
THIS UNIT MUST BE
INSTALLED IN AN
AREA PROTECTED FROM
THE ELEMENTS, SUCH AS WIND, RAIN, WATER SPRAY OR DRIP.
90' F
‘03 F
Lli ti6A
d Lay carton on rear face and break open bottom flaps.
2 Set carton upright with all four flaps outward, See Figure 3.
3 Lift container up and off of machtne.
4 Remove all tape and packaging material from the outside and inside of the cabinet. See Figure 4.
5R emove the front grill; take out the screws secur- ing the grill at the bottom and Ilft It free of cabinet.
6 Turn the fan by hand to make certarn It moves freely.
?I- oosen thumb screws holding cutter grid and water pan to “thumb tight.”
lUTILITIES
WATERELECTRICITYDRAIN
1 Place | unrt | so the front | side | will | be completely |
unobstructed. | to provide | proper | air | flow |
2 Area should be well ventilated with temperature above 55qF and below 110°F. Best results are obtained between 70°F and 90°F.
3 Provrslon for electnclty. water and drain connec- tions should be determined.
4 The unit may be closed in on the top and three
sides. but the front MUST BE unobstructed for air
circulation and proper operation lnstallatlon should be such that the cabinet can be moved
forward for servlcrng If necessary
. LEVEL UNIT
1 After placrng untt In posltlon. check to make certain the unrt IS level side to side and front to back
2A ccurate leveling IS essential for proper operation
3 Unit should be shimmed so that It IS solid as well as
level The shims should be of hard permanent type matenal such as masonlte.
4 If required by sanitation code, seal the cabinet to the floor wrth an approved caulking compound.
OBSERVE LOCAL CODES
Each installation is unique but will require:
1 A cold water Inlet of 114”OD soft copper tubing and a
3