FOR THE ELECTRICIAN
ELECTRICAL REQUIREMENTS
A 115 Volt, 60 Hz, AC only, 15 Amp fused electrical supply IS required (time delay fuse or circuit breaker is recommended).
It is recommended that a separate circuit, serving only this appliance, be provided. DO NOT use an extension cord.
ALTERNATE
GROUNDING METHOD
DO NOT, UNDER ANY CIRCUMSTANCES, REMOVE THE POWER SUPPLY CORD GROUND PRONG.
ELECTRICAL GROUND IS REQUIRED ON THIS APPLIANCE.
RECOMMENDED
GROUNDING MtHOD
DO NOT, UNDER ANY CIRCUMSTANCES, REMOVE THE POWER SUPPLY CORD GROUND PRONG.
For your personal safety, this appliance must be grounded. This appliance is equipped with a power supply cord having a
Electrical Code and local codes and ordinances. If a mating wall receptacle is not available, it is the personal responslbillty
and obligation of the customer to have a properly grounded
II | III | ||
GROUNDING | |||
TYPE |
|
WALL RECEPTACLE
NG
NDING
\POWER SUPPLY CORD
FIGURE 6
If changing and properly grounding the wall recepta-
cle IS lmposslble and where local codes permit
(consult your electrlcal inspector). a temporary adapter may be plugged into the existing
receptacle to mate with the
cord. See Figure 7. THIS, HOWEVER, IS NOT RE-
COMMENDED.
If this IS done, you musT connect the grouncllng eyelet on the adapter to the wall receptacle cover plate screw and from this same screw, you must connect a separate copper ground wire (No 4 mlnimum) to a qrounded cold water pipe’ See Flgu:e 7 Do not ground to a gas supply pipe. Do not connect to
electrical supply until appliance IS permanently grounded.
ground and not be Interrupted by plastic rubber or other
electrIcally lnsulatlng connectors (including waler meter or pump) wlthout addlng a lumper wire at these connectlons
GROUND ASSEMBLY
(ATTACH TO GROUNDED COLD WATER PIPE)
ELECTRICALLY
GROUNDED COLD
WATER PIPE (REMOVE
GROUND WIRE (#4 i’llNlMUMl
/
KGROUNDING
EYELET a
1
i
ASSEMBLY | f |
WALL RECEPTACLE |
POWER SUPPLY CORD
FIGURE 7