UNIT WIRING DIAGRAM

UNIT WIRING DIAGRAM

This model operates at 115 volts except for the cutter grid circuit which operates at 8.5 volts at 1 amp.

he compressor runs at all times except when the

bin thermostat becomes satisfied and opens up. This de-energizes the system except for the trans- former and cutter grid.

Under normal operating conditions, when the

evaporator reaches the preset temperature (+lO’

to -3OF, depending on thickness of ice) the

evaporator thermostat opens, terminating op- eration of the fan motor and pump motor. The hot gas solenoid and the water valve solenoid are

energized at this time and remain so until the

evaporator reaches 38 + 2’ F.

DANGER: ELECTRIC SHOCK HAZARD

DISCCNNECTKhvER BEFORE SERVICIW LN,T

MAXIMUM FUSE SIZE: ISaMPs

NOTE‘CCWT.TS?+43’“4IN FREEZINGCYCLE

CUBELET CUTTER GRIDS

I-

8

CUBE CUTTER GRID

FUSE GRID

YOUR UNIT MAY OR MAY NOT BE EQUIPPED WITH A CUTTER GRID FUSE.

1%” x 1%” Cube Grid

CHECK OPERATION

v Start the unrt by turnrng the service switch to “ON” and opening the line water valve.

vNOTE: Left is “OFF” - Middle is “ON” - Right

is “CLEAN.” In “CLEAN” position, only the pump operates.

vCheck condenser fan to make sure it is revolving.

vWater will not enter pump pan until freezing plate gets cold and machine goes into a harvest cycle.

vCheck for even water flow over freezing plate. Unit must be level for proper operation.

vCheck for desired cube thickness and after 24

hours adjust if necessary. Maximum ice yield will be obtained with ice thickness at J/2” to H”.

vReplace grill.