Whirlpool 6ADG 7554 WHM S E R V I C E, Technical data, Flow rates/ Inlet volume, Drain pump motor

Models: 6ADG 7554 WHM

1 17
Download 17 pages 33.01 Kb
Page 3
Image 3
Flow rates/ Inlet volume

S E R V I C E

Technical data

Whirlpool Europe

6ADG 7554 WHM

08.08.2002 / Page 3

Customer Service

8542 554 53710

Doc. No: 4812 718 18228

 

 

 

Spray arms, turning rhythm at alternating spray system

Turning starts every time with the upper spray arm

Pre wash Lower arm ~3min, Upper arm ~1min Main wash Lower arm ~3min, Upper arm ~5min Intermediate rinse

Lower arm ~2min, Upper arm ~2min Final rinse Lower arm ~2min, Upper arm ~2min Service Test program

Lower arm ~30sec, Upper arm ~30sec

Remark: When switching of the main switch or interrupt the mains during the Test Program runs, then the alternating of the spray arms change in the test program to the rhythm of main wash 5/3 min.

Important: To leaf the Test program is possible by made a break by customer (pushing the start button for 1.5 sec.)

After finishing the test program (End LED shines and/or Start LED goes of) must the appliance be switched off.

If this will not be done, then the next normal wash will be made with the frequency of the Service Test Program ~30/30sec.

Flow rates/ Inlet volume

 

 

Flow meter (at 0.3 bar

 

 

= quantity 1.1 l/min)

208

lmp/l

Spray pump

45 - 65

l/min

Drain pump

16

l/min

Pump height max.

1.1

m

Inlet valve

4

l/min

Spray arm lower

~ 33

l/min

Sprayarm upper

~ 27

l/min

Shower top

~ 8

l/min

Electrical base data

 

 

Voltage

240

V

Frequency

50

Hz

Total power

2.4

kW

Fuse

10

A

Motor

Spray pump motor alternating spray system

Voltage

220/ 240

V

Power consumption

125

W

HI

79

Ω

HA

60

Ω

Capacitor

4

μ F

Drain pump motor

 

 

Voltage

220/ 240

V

Power consumption

30

W

Resistance

146

Ω

Page 3