Electrical Requirements For Your Air Conditioner

Electrical Requirements For Your Air Conditioner

BELOW ARE ELECTRICAL PLUG VARIATIONS, CHOOSE THE ONE WHICH MATCHES THE AMPERE RATING OF YOUR UNIT. THE NUMBER OF AMPERES IS PRINTED ON THE SERIAL LABEL, ATTACHED TO THE FRONT OF THE UNIT, BEHIND THE FRONT PANEL (SEE PAGE 2).

Chart-A

PLUG TYPE

SEE

ELECTRICAL

 

 

REQUIREMENTS

 

 

 

 

 

3-PRONG

 

 

 

n

 

GROUNDING

PLUG

 

 

 

 

 

 

 

 

 

S’PRONG

 

A115 volt models

 

 

GROUNDING

For

with

 

TYPE WALL

 

RECEPTACLE

serial

plate amperes

up

 

 

POWER

SUPPLV

through

12.0

 

 

 

 

 

An REQUIREMENTSELECTRICAL

For 115 volt models with serial plate amperes up through 12.0

OBSERVE ALL LOCAL GOVERNING CODES AND ORDINANCES

Do not, under any circumstances, remove the power supply cord ground prong.

RECEPTACLE WIRING

RECEPTACLE WIRING should be at least as large as 14 gauge. Use copper wire only. It is the

personal responsibility and obligation of the customer to provide proper and adequate receptacle wiring installed by a qualified electri-

cian. OBSERVE NATIONAL ELECTRICAL

CODE AND ALL LOCAL GOVERNING CODES AND ORDINANCES.

For 230 volt and 2301208 volt models with serial plate amperes up through 12.0

Electrical Requirements

A 115 volt (103.5 min., 126.5 max.) 60 hertz AC only, 15 ampere fused electrical supply is required (time delay fuse or time delay circuit breaker re- quired). It is required that a separate circuit, serving only this appliance, be provided. Do not use an extension cord.

For 230 volt and 2301208 volt models with serial plate amperes up through 16.0

Dl

For 230 volt and 2301208 volt models with serial plate amperes up through 24.0

Electrical Connection

Electrical Ground is Required on this Appliance

RECOMMENDED GROUNDING METHOD

For your personal safety, this appliance must be grounded. This appliance is equipped with a power supply cord having a 3-prong grounding plug. To minimize possible shock hazard, the cord must be plugged into a mating 3-prong grounding type wall receptacle, grounded in accordance with the National Electrical Code and local codes and ordinances. If a mating wall receptacle is not available, it is the peisonal responsibility and obligation of the customer to have a properly grounded 3-prong wall receptacle installed by a qualified electrician. See Figure 1 on page 4.