5
Specific electrical requirements are listed in the chart below.
Follow the requirements for the type of plug on the power su pply
cord. Recommended ground method
For your personal safety, this air conditioner must be grounded.
This air conditioner is equipped with a power supply cord having
a grounded 3 prong plug. To minimize possible shock hazard, the
cord must be plugged into a mating, grounded 3 prong outlet,
grounded in accordance with all local codes and ordinances. If a
mating outlet is not available, it is the customer's responsibility to
have a properly grounded 3 prong outlet installed by a qualified
electrical installer.
It is the customer's responsibility:
To contact a qualified electrical installer.
To assure that the electrical installation is adequate and in
conformance with National Electrical Code, ANSI/NFPA 70 -
latest edition, and all local codes and ordinances.
Copies of the standards listed may be obtained from:
National Fire Protection Association
One Batterymarch Park
Quincy, Massachusetts 02269
INSTALLATION INSTRUCTIONS

Unpacking

Remove packaging materials
Remove and properly dispose of packaging materials.
Remove tape and glue residue from surfaces before turning
on the air conditioner. Rub a small amount of liquid dish soap
over the adhesive with your fingers. Wipe with warm water
and dry.
Do not use sharp instruments, rubbing alcohol, flammable
fluids, or abrasive cleaners to remove tape or glue. These
products can damage the surface of your air conditioner.
Handle air conditioner with care.
1. Remove air conditioner from carton and place on cardboard.
2. Remove shipping screw from side wall of cabinet.
3. Pull control knobs off (on some models).
4. Remove front panel from air conditioner and set aside.
5. Remove ground screw and ground wire from front of air
conditioner base. Save ground screw.
6. Pull on handle to slide air conditioner out of cabinet. Place air
conditioner on cardboard.
NOTE: Do not lift, push, pull or remove any expanded
polystyrene (foam) from inside the air conditioner. It is not
packing material.
Power supply cord
plug outlet Wiring requirements
115 volt (103.5 min. -
126.5max.)
0-12 amps
15-amp time-delay fuse or
circuit breaker
Use on single outlet circuit only.
230 volt (207 min. - 253 max.)
230/208 volt (197.6 min. -
253 max.)
0-12 amps
15-amp time-delay fuse or
circuit breaker
Use on single outlet circuit only.
¹⁄₄"
(0.6 cm)
A.Shipping screw

Excessive Weight Hazard

Use two or more people to move and install

air conditioner.

WARNING

Failure to do so can result in back or other injury.

A
A.Green ground wire
B.Ground screw
A.Handle
A
B
+
+
+
A