Whirlpool ACSl02XE, ACS072XE warranty amperes from, volt models with through, Receptacle wiring

Models: ACS072XE ACSl02XE

1 22
Download 22 pages 63.96 Kb
Page 7
Image 7
amperes from 7.6

115 volt models with through 12.0

Receptacle wiring

Receptacle wiring should be a minimum of 14 gauge. Use copper wire only. It is the responsibility of the consumer to provide proper and adequate receptacle wiring, installed by a qualified electrician. Observe National Electrical Code and all local governing codes and ordinances.

amperes from 7.6

Electrical requirements

A 115 volt (103.5 min., 126.5 max.), 60 Hz, AC only, 15 ampere fused electrical supply is required (time delay fuse or time delay circuit breaker required). It is required that a separate circuit, serving only this air condi- tioner, be provided.

Electrical connection

Electrical ground is required on this air conditioner.

Recommended grounding method

For your personal safety, this air conditioner must be grounded. This air conditioner is equipped with a power supply cord having a 3-prong grounding plug. To mini- mize possible shock hazard, the cord must be plugged into a mating 3-prong grounding-type wall receptacle, grounded in accordance with the National Electrical Code (ANSVNFPA 70 - latest edition) and local codes and ordinances. If a mating wall receptacle is not available, it is the responsi- bility of the customer to have a properly grounded 3-prong wall receptacle installed by a qualified electrician.

3-prong grounding Plug

3-prong grounding type wall

Poker

L receptacle

(single outlet)

SUPPlY

 

cord

 