115 volt models with through 12.0
Receptacle wiring
Receptacle wiring should be a minimum of 14 gauge. Use copper wire only. It is the responsibility of the consumer to provide proper and adequate receptacle wiring, installed by a qualified electrician. Observe National Electrical Code and all local governing codes and ordinances.
amperes from 7.6
Electrical requirements
A 115 volt (103.5 min., 126.5 max.), 60 Hz, AC only, 15 ampere fused electrical supply is required (time delay fuse or time delay circuit breaker required). It is required that a separate circuit, serving only this air condi- tioner, be provided.
Electrical connection
Electrical ground is required on this air conditioner.
Recommended grounding method
For your personal safety, this air conditioner must be grounded. This air conditioner is equipped with a power supply cord having a
Poker | L receptacle | |
(single outlet) | ||
SUPPlY | ||
| ||
cord |
|