PLUG TYPE | ELECTRICAL REQUIREMENTS |
Power supply cord
- Ctprong grounding lypa wall
NtfTPtaCl~
115 volt models with amperes up through 7.5
For 115 volt models with amperes from 7.6 to 12.0
115 volt models with through 7.5
Receptacle wiring
Receptacle wiring should be a minimum of 14 gauge. Use copper wire only. It is the responsibility of the consumer to provide proper and adequate receptacle wiring, installed by a qualified electrician. Observe National Electrical Code and all local governing codes and ordinances.
Electrical connection
Electrical ground is required on this air conditioner.
Recommended grounding method
For your personal safety, this air conditioner must be grounded. This air conditioner is equipped with a power supply cord having a
amperes up
Electrical requirements
A 115 volt (103.5 min., 126.5 max.), 60 Hz, AC only, 15 ampere fused electrical supply is required (time delay fuse or time delay cir- cuit breaker required). It is required that a separate circuit, serving only this air condi- tioner, be provided.