Whirlpool ACS072XE volt models with through, amperes up, Receptacle wiring, Electrical connection

Models: ACS072XE ACSl02XE

1 22
Download 22 pages 63.96 Kb
Page 6
Image 6
115 volt models with through 7.5

PLUG TYPE

ELECTRICAL REQUIREMENTS

Power supply cord

- Ctprong grounding lypa wall

NtfTPtaCl~

115 volt models with amperes up through 7.5

For 115 volt models with amperes from 7.6 to 12.0

115 volt models with through 7.5

Receptacle wiring

Receptacle wiring should be a minimum of 14 gauge. Use copper wire only. It is the responsibility of the consumer to provide proper and adequate receptacle wiring, installed by a qualified electrician. Observe National Electrical Code and all local governing codes and ordinances.

Electrical connection

Electrical ground is required on this air conditioner.

Recommended grounding method

For your personal safety, this air conditioner must be grounded. This air conditioner is equipped with a power supply cord having a 3-prong grounding plug. To mini- mize possible shock hazard, the cord must be plugged into a mating 3-prong grounding-type wall receptacle, grounded in accordance with the National Electrical Code (ANSVNFPA 70 - latest edition) and local codes and ordinances. If a mating wall receptacle is not available, it is the responsi- bility of the customer to have a properly grounded 3-prong wall receptacle installed by a qualified electrician.

amperes up

Electrical requirements

A 115 volt (103.5 min., 126.5 max.), 60 Hz, AC only, 15 ampere fused electrical supply is required (time delay fuse or time delay cir- cuit breaker required). It is required that a separate circuit, serving only this air condi- tioner, be provided.