InstallationInstructions

Eloctrlcal

Rsqulramsnts

 

 

 

Continusd

 

 

 

 

Electrically

 

 

Ground

assembly

grounded

metal

 

(attach to grounded

coid water pipe

 

metal cold

water pipe)

(removepelnt,etc.) 7

f

1

 

Grounded

eyelet

 

 

 

all

receptacle

~‘-

1 t--Gmundlng-

Temporary grounding msthod

If changing and property grounding the wall recap tacle is impossible and where local codes permit (consuft your electrical inspector), a temporary adapter may bs plugged into the existing P-prong wall receptacle to mate with the 3-prong power supply cord. This, however, is not recommended.

If this is done, however, you must connect the grounded eyelet on the adapter to the wall mcep tacfe cover plate screw and from this same screw, you must connect a separate copper ground wire (Xl4 minimum) to a grounded cold water pipe.

‘Do not ground to a gas supply pipe. Do not connect to electrfcal supply until appliance is grounded. Do not, under any circumstances, remove the power supply cord grounding prong. ‘Cold water pipe must have metal continuity to electrical ground and not be interrupted by pIas- tic, rubber or other electrically insulating corlneC- tors (including water meter or pump) wfthout adding a jumper wire at these connections.

InstallationInstructions

For models ACS602, ACS802 and ACSlOP, follow installation instructions below. For model ACC802, follow installation instructions on page 8.

InstallationInstructionsfor modelsACS602,ACM02 andACSIM

To help avoid any installation problems and to help assure trouble-free perfomtance of your new air conditioner, read these installation instructions, as well as the operating instructions and electrical requirements before installing your unit.

Personal InJury Hazard

l Because thls air conditioner wslghs about 90 to 105 pounds, it is recommended that you have somsons hsip you Install your nsw unit and that you both uss propsr lift- ing techniques.

l Inspect the condition of ths wlndow whefa ths air condftionsr will be Installed. Bs sure it wlii support the weight of ths unit.

l mh appliance must be Instalisd accord ing to ail applicable codes and ordinances.

0 Handle ths air wndttlonsr wlth care. Watch out for the sharp metal ffns on ths front and rear colis.

l Be sum air conditioner doss not fall oui of window during or aftsr lnstaliatlon.

mDo not uss ths collected watsr for drinking purposes. It is not sanitary.

Faiiurs to follow ths abovs prsoautions could msuit In psrsonal Injury.