Electrical Requirements
Continued
1 ~;I;:::;;~~~~rd.. | , |
Domg so can result In death, fire, or |
|
Electrical Shock Hazard
Plug into a grounded three prong outlet. Do not remove ground prong.
Do not use an adapter.
Do not fuse neutral or grounding circuit. Do not use air conditioner with front panel removed.
Failure to follow these instructions can result in death, electrical shock, or serious injury.
receptacle
230/208volt modelswith amperesupthrough12.0
Receptacle wiring
Receptacle wiring should be a minimum of 14 gauge. Use copper wire only. It is the responsibility of the consumer to provide proper and adequate receptacle wiring, installed by a qualified electrician. Observe National Electrical Code and all local governing codes and ordinances.
Electrical requirements
A 230/208 volt (197.6 min., 253 max.), 60 Hz, AC only, 15 ampere fused electrical supply is required (time delay fuse or time delay circuit breaker required). It is required that a separate circuit, serving only this air conditioner, be provided.
Electrical connection
Electrical ground is required on this air conditioner.
Recommended grounding method
For your personal safety, this air conditioner must be grounded. This air conditioner is equipped with a power supply cord having a